The effect of prolonged steep head-down laparoscopy on the optical nerve sheath diameter
Authors:
- 5 November 2019
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (6) , 1295-1302
Abstract
Both the steep head-down position and pneumoperitoneum increase the intracranial pressure (ICP), and their combination for a prolonged period during laparoscopic radical prostatectomy (LRP) might influence the central nervous system homeostasis. Changes in optic nerve sheath diameter (ONSD) may reflect those in ICP. This study aims to quantify the change in ONSD in response to peritoneal CO2 insufflation and steep Trendelenburg position during LRP. ONSD was measured by ultrasound in 20 patients undergoing LRP and ten awake healthy volunteers. In patients, ONSD was assessed at baseline immediately after induction of general anesthesia in supine position, 10 and 60 min from baseline in a 25° head-down position during pneumoperitoneum, and after deflation of pneumoperitoneum with the patient supine at 0° angle. ONSD in controls was assessed at baseline with the patient lying supine, after 10 and 60 min of 25° head-down position, and 10 min after repositioning at 0° angle. ONSD increased significantly in both patients and controls (p < 0.0001) without between-group differences. The mean increase was 10.3% (95% CI 7.7–12.9%) in patients versus 7.5% (95% CI 2.5–12.6%) in controls (p = 0.28), and didn’t affect the time to recovery from anesthesia. In the studied patients, with a limited increase of end-tidal CO2 and airway pressure, and low volume fluid infusion, the maximal ONSD was always below the cut-off value suspect for increased ICP. ONSD reflects the changes in hydrostatic pressure in response to steep Trendelenburg position, and its increase might be minimized by careful handling of general anesthesia.Keywords
This publication has 34 references indexed in Scilit:
- Ultrasonography of the optic nerve in neurocritically ill patientsActa Anaesthesiologica Scandinavica, 2011
- Optic nerve sonography: a new window for the non-invasive evaluation of intracranial pressure in brain injuryEmergency Medicine Journal, 2009
- The Effects of Steep Trendelenburg Positioning on Intraocular Pressure During Robotic Radical ProstatectomyAnesthesia & Analgesia, 2009
- The effect of pneumoperitoneum in the steep Trendelenburg position on cerebral oxygenationActa Anaesthesiologica Scandinavica, 2009
- Posterior Ischemic Optic Neuropathy After Minimally Invasive ProstatectomyJournal of Neuro-Ophthalmology, 2007
- The role of optic nerve ultrasonography in the diagnosis of elevated intracranial pressureEmergency Medicine Journal, 2007
- Optimizing the intraoperative management of carbon dioxide concentrationCurrent Opinion in Anaesthesiology, 2006
- Elevated Intracranial Pressure Detected by Bedside Emergency Ultrasonography of the Optic Nerve SheathAcademic Emergency Medicine, 2003
- Changes in Cerebral Blood Volume with Changes in Position in Awake and Anesthetized SubjectsAnesthesia & Analgesia, 2000
- Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion testsJournal of Neurosurgery, 1997