Double common-path interferometer for flexible optical probe of optical coherence tomography
Authors:
Open Access
- 4 January 2012
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (2) , 1102-1112
Abstract
A flexible curled optical cord is useful for a common-path optical coherence tomography (OCT) system because a bending-insensitive arbitrary length can be chosen for the endoscopic imaging probe. However, there has been a critical problem that the partial reflector needs to be placed in between the sample and the objective lens. It limits the structure design of optical probe and leads to a low transverse resolution OCT imaging. Instead of a conventional single common-path interferometer, we propose a novel double common-path interferometer configuration in order to generate an interference signal that is independent of the optical distance between the partial reflector and sample. Due to the limitless tuning of the objective distance, an objective lens with a high numerical aperture (NA) up to 0.85 can be successfully used for phase-sensitive optical coherence tomography to achieve a 3-dimensional profile image of a transverse resolution of 0.7 μm. The intensity and phase terms of the interference signal can be obtained simultaneously from a Fourier-domain mode locked swept laser source for fast data acquisition with a phase stability of 979 pm.Keywords
This publication has 17 references indexed in Scilit:
- Optical Coherence Tomography Based on a Continuous-wave Supercontinuum Seeded by Erbium-doped Fiber's Amplified Spontaneous EmissionJournal of the Optical Society of Korea, 2010
- Flexible Curled Optical Cord for Bending-Insensitive Optical Imaging DeliveryIEEE Journal of Selected Topics in Quantum Electronics, 2009
- Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasersOptics Letters, 2007
- Swept source optical coherence microscopy using a Fourier domain mode-locked laserOptics Express, 2007
- Endoscope-tip interferometer for ultrahigh resolution frequency domain optical coherence tomography in mouse colonOptics Express, 2006
- All-fiber common-path optical coherence tomography: sensitivity optimization and system analysisIEEE Journal of Selected Topics in Quantum Electronics, 2005
- Common-path interferometer for frequency-domain optical coherence tomographyApplied Optics, 2003
- Optical coherence tomography and microscopy in gastrointestinal tissuesIEEE Journal of Selected Topics in Quantum Electronics, 1996
- Optical Coherence TomographyScience, 1991