Effects of misalignment during corneal topography
Authors:
- Isabelle BrunetteIBIsabelle Brunette
- 1 September 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (9) , 1522-1529
Abstract
To evaluate consequences of misalignment during corneal topography. Maisonneuve-Rosemont Hospital, Montreal, Quebec, Canada. Twenty-nine healthy subjects were enrolled in a study of 2 types of misalignment during Orbscan topography acquisition. The first was rotation, which was defined as angular deviation of the subject's visual axis away from the central fixation target, and the second was translation, defined as off-center displacement of the joined half slits on the computer screen during alignment by the technician. The effect of vertical and horizontal misalignments, by rotation or translation, was assessed. Study parameters included simulated keratometries (SimKs), mean corneal power (mean power), and corneal apex (R) and the asphericity factor (Q) values. Inferior-superior (I-S) and temporal-nasal (T-N) indices were calculated. Differences in parameter values between aligned and misaligned positions were studied. A mathematical model was also developed to simulate rotational and translational misalignment and consolidate clinical experimentation. The mean SimK values were slightly but significantly affected by rotation. The I-S value increased significantly with downward rotation and decreased with upward rotation of the eye, while T-N values increased significantly with temporal rotation and decreased with nasal rotation. The R and Q values increased with rotation. Overall, the topography parameters were minimally affected by translation. Comparable results were obtained with the theoretical model. Rotational misalignment of the eye during acquisition influenced topography more than the translational misalignment during focusing by the technician. Rotational misalignment induced corneal asymmetry on elevation and curvature maps as well as pseudokeratoconus patterns.Keywords
This publication has 15 references indexed in Scilit:
- Neural network-based system for early keratoconus detection from corneal topographyJournal of Biomedical Informatics, 2002
- Objective Screening Methods for Prior Refractive Surgery in Donor TissueCornea, 2002
- Keratoconus evaluation using the Orbscan Topography SystemJournal of Cataract & Refractive Surgery, 2000
- Videokeratographic changes after laser in situ keratomileusis to correct high myopiaJournal of Cataract & Refractive Surgery, 1999
- Significance of corneal topography in predicting patient complaints after photorefractive keratectomyJournal of Cataract & Refractive Surgery, 1999
- Corneal topography in asymptomatic family members of a patient with pellucid marginal degenerationAmerican Journal of Ophthalmology, 1999
- Topographic Pattern and Apex Location of Keratoconus on Elevation Topography MapsCornea, 1998
- Analysis of the Inherent Error of the TMS-1 Topographic Modeling System in Mapping a Radially Aspheric SurfaceCornea, 1995
- The Effect of Poor Fixation on Computer-assisted Topographic Corneal AnalysisOphthalmology, 1994
- The Topography of Normal CorneasArchives of Ophthalmology (1950), 1989