A Knowledge-Based Modeling for Plantar Pressure Image Reconstruction
Authors:
- 9 May 2014
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 61 (10) , 2538-2549
Abstract
It is known that prolonged pressure on the plantar area is one of the main factors in developing foot ulcers. With current technology, electronic pressure monitoring systems can be placed as an insole into regular shoes to continuously monitor the plantar area and provide evidence on ulcer formation process as well as insight for proper orthotic footwear design. The reliability of these systems heavily depends on the spatial resolution of their sensor platforms. However, due to the cost and energy constraints, practical wireless in-shoe pressure monitoring systems have a limited number of sensors, i.e., typically K<;10. In this paper, we present a knowledge-based regression model (SCPM) to reconstruct a spatially continuous plantar pressure image from a small number of pressure sensors. This model makes use of high-resolution pressure data collected clinically to train a per-subject regression function. SCPM is shown to outperform all other tested interpolation methods for K<;60 sensors, with less than one-third of the error for K=10 sensors. SCPM bridges the gap between the technological capability and medical need and can play an important role in the adoption of sensing insole for a wide range of medical applications.Keywords
This publication has 27 references indexed in Scilit:
- Registration of pedobarographic image data in the frequency domainComputer Methods in Biomechanics and Biomedical Engineering, 2010
- What are the most effective interventions in preventing diabetic foot ulcers?International Wound Journal, 2008
- Principal Component Analysis2005
- Voronoi cell finite difference method for the diffusion operator on arbitrary unstructured gridsInternational Journal for Numerical Methods in Engineering, 2003
- Speaker Verification Using Adapted Gaussian Mixture ModelsDigital Signal Processing, 2000
- Survey: interpolation methods in medical image processingIEEE Transactions on Medical Imaging, 1999
- Spatial resolution in plantar pressure measurementMedical Engineering & Physics, 1997
- Frequency content of normal and diabetic plantar pressure profiles: Implications for the selection of transducer sizesJournal of Biomechanics, 1996
- The Effect of Callus Removal on Dynamic Plantar Foot Pressures in Diabetic PatientsDiabetic Medicine, 1992
- Data Dependent Triangulations for Piecewise Linear InterpolationIMA Journal of Numerical Analysis, 1990