Accuracy and precision of smartphone applications and commercially available motion sensors in multiple sclerosis
Open Access
- 1 January 2016
- journal article
- research article
- Published by SAGE Publications in Multiple Sclerosis Journal – Experimental, Translational and Clinical
- Vol. 2
Abstract
Background: There is increased interest in the application of smartphone applications and wearable motion sensors among multiple sclerosis (MS) patients. Objective: This study examined the accuracy and precision of common smartphone applications and motion sensors for measuring steps taken by MS patients while walking on a treadmill. Methods: Forty-five MS patients (Expanded Disability Status Scale (EDSS) = 1.0–5.0) underwent two 500-step walking trials at comfortable walking speed on a treadmill. Participants wore five motion sensors: the Digi-Walker SW-200 pedometer (Yamax), the UP2 and UP Move (Jawbone), and the Flex and One (Fitbit). The smartphone applications were Health (Apple), Health Mate (Withings), and Moves (ProtoGeo Oy). Results: The Fitbit One had the best absolute (mean = 490.6 steps, 95% confidence interval (CI) = 485.6–495.5 steps) and relative accuracy (1.9% error), and absolute (SD = 16.4) and relative precision (coefficient of variation (CV) = 0.0), for the first 500-step walking trial; this was repeated with the second trial. Relative accuracy was correlated with slower walking speed for the first ( rs = −.53) and second ( rs = −.53) trials. Conclusion: The results suggest that the waist-worn Fitbit One is the most precise and accurate sensor for measuring steps when walking on a treadmill, but future research is needed (testing the device across a broader range of disability, at different speeds, and in real-life walking conditions) before inclusion in clinical research and practice with MS patients.Keywords
This publication has 9 references indexed in Scilit:
- Remote Tracking of Walking Activity in MS Patients in a Real-World Setting (P3.209)Neurology, 2015
- Top 10 Research Questions Related to Physical Activity and Multiple SclerosisResearch Quarterly for Exercise and Sport, 2015
- Comparison of Step Outputs for Waist and Wrist Accelerometer Attachment SitesMedicine & Science in Sports & Exercise, 2015
- Accuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity DataJAMA, 2015
- Accuracy of StepWatch™ and ActiGraph Accelerometers for Measuring Steps Taken among Persons with Multiple SclerosisPLOS ONE, 2014
- Does an accelerometer accurately measure steps taken under controlled conditions in adults with mild multiple sclerosis?Disability and Health Journal, 2011
- Confirmation and extension of the validity of the Multiple Sclerosis Walking Scale-12 (MSWS-12)Journal of the Neurological Sciences, 2008
- Accuracy of two electronic pedometers for measuring steps taken under controlled conditions among ambulatory individuals with multiple sclerosisMultiple Sclerosis Journal, 2005
- Rating neurologic impairment in multiple sclerosisNeurology, 1983