Monitoring environmental cleanliness on two surgical wards
- 27 September 2008
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 18 (5) , 357-364
Abstract
Ten hand-touch sites were screened weekly on two surgical wards over two consecutive six-month periods. The results were analysed using hygiene standards, which specify (i) an aerobic colony count (ACC) > 2.5 cfu/cm2, and (ii) presence of coagulase-positive staphylococci, as hygiene failures. Sites most often failing the standards were beds and hoist (64%: 33 of 52 weeks), bedside lockers (62%: 32 of 52) and overbed tables (44%: 23 of 52). Methicillin-susceptible/resistant Staphylococcus aureus (MSSA/MRSA) were more often recovered from lockers, overbed tables and beds. Recovery of MSSA/MRSA at any site was significantly associated with an ACC > 2.5 cfu/cm2 from that site (p = 0.001; OR: 3.35 [95% CI 1.79, 6.28]). In addition, total ACC's > 2.5 cfu/cm2 each week were significantly associated with weekly bed occupancies > 95% (p = 0.0004; OR: 2.94 [95% CI 1.44, 6.02]). Higher microbial growth levels from hand-touch sites reflect weekly bed occupancies and indicate a risk for both resistant and susceptible S. aureus. These organisms are more likely to be recovered from near-patient sites on the ward.Keywords
This publication has 24 references indexed in Scilit:
- Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition: the case for hospital cleaningThe Lancet Infectious Diseases, 2008
- Bed occupancy, turnover intervals and MRSA rates in English hospitalsBritish Journal of Nursing, 2006
- MRSA acquisition in an intensive care unitAmerican Journal of Infection Control, 2006
- Acquisition of Nosocomial Pathogens on Hands After Contact With Environmental Surfaces Near Hospitalized PatientsInfection Control & Hospital Epidemiology, 2004
- How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitalsJournal of Hospital Infection, 2004
- Bed occupancy and overcrowding as determinant factors in the incidence of MRSA infections within general ward settingsJournal of Hospital Infection, 2003
- A purpose built MRSA cohort unitJournal of Hospital Infection, 2000
- An evaluation of hospital cleaning regimes and standardsJournal of Hospital Infection, 2000
- Mopping up hospital infectionJournal of Hospital Infection, 1999
- Environmental Contamination Due to Methicillin-Resistant Staphylococcus aureus: Possible Infection Control ImplicationsInfection Control & Hospital Epidemiology, 1997