Two-dimensional transthoracic measure of mitral annulus in mitral valve prolapse and moderate to severe regurgitation: a method comparison analysis with three-dimensional transesophageal echocardiography
Open Access
- 12 June 2024
- journal article
- research article
- Published by Springer Nature in Journal of Cardiovascular Imaging
- Vol. 32 (1) , 1-10
Abstract
Background: Mitral annulus (MA) area is derived during transthoracic echocardiography (TTE) assuming of a circular shape using the MA diameter from the apical 4 chamber (A4c) view. Since the MA is not a circular structure, we hypothesized that an elliptical model using parasternal long-axis (PLAX) and apical 2 chamber (A2c) view measured MA diameters would have better agreement with 3-dimensional transesophageal echocardiography (3D TEE) measured MA in degenerative mitral valve disease (DMVD). Methods: Seventy-six patients with moderate-to-severe DMVD had 2D TTE and 3D TEE performed. MA area was measured retrospectively using semi-automatic modeling of 3D data (3D TEEsa) and considered as the reference method. MA diameters were measured using different 2D TTE views. MA area was calculated using assumptions of a circular or an elliptical shape. 2D TTE derived and 3D TEEsa. MA areas were compared using linear regression and Bland-Altman analysis. Results: The median MA area measured at 3D TEEsa was 1,386 (1,293–1,673) mm2. With 2D TTE, the circular model using A4c view diameter resulted in a small systematic underestimation of MA area (6%), while the elliptical model using PLAX and A2c diameters resulted in 25% systematic underestimation. The standard deviations of the distributions of inter-method differences were wide for all 2D TTE methods (265–289 mm2) when compared to 3D TEEsa, indicating imprecision. Conclusions: When compared with 3D TEEsa modeling of the MA as the reference, the assumption of a circular shape using A4c TTE view diameter was the method with the least systematic error to assess MA area in DMVD and moderate to severe regurgitation.Keywords
This publication has 27 references indexed in Scilit:
- Role of Cardiac Computed Tomography in Planning Transcatheter Mitral Valve Replacement (TMVR)Current Cardiology Reports, 2022
- Recommendations for Noninvasive Evaluation of Native Valvular RegurgitationJournal of the American Society of Echocardiography, 2017
- Clinical Implications of Three-Dimensional Real-Time Color Doppler Transthoracic Echocardiography in Quantifying Mitral Regurgitation: A Comparison with Conventional Two-Dimensional MethodsJournal of the American Society of Echocardiography, 2017
- Quantitative Modeling of the Mitral Valve by Three-Dimensional Transesophageal Echocardiography in Patients Undergoing Mitral Valve Repair: Correlation with Intraoperative Surgical TechniqueJournal of the American Society of Echocardiography, 2015
- Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular ImagingJournal of the American Society of Echocardiography, 2015
- Quantitative Analysis of Mitral Annular Geometry and Function in Healthy Volunteers Using Transthoracic Three-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 2014
- Anatomy of the Mitral Valve ApparatusCardiology Clinics, 2013
- Quantification of Mitral Valve Anatomy by Three-Dimensional Transesophageal Echocardiography in Mitral Valve Prolapse Predicts Surgical Anatomy and the Complexity of Mitral Valve RepairJournal of the American Society of Echocardiography, 2012
- Accurate Measurement of Mitral Annular Dimensions by Echocardiography: Importance of Correctly Aligned Imaging Planes and Anatomic LandmarksJournal of the American Society of Echocardiography, 2009
- Contribution of ischemic mitral regurgitation to congestive heart failure after myocardial infarctionJACC, 2005