Apple Sauce Improves Detection of Esophageal Motor Dysfunction During High-Resolution Manometry Evaluation of Dysphagia
Open Access
- 23 December 2010
- journal article
- research article
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 56 (6) , 1723-1728
Abstract
Background Esophageal manometry utilizes water swallows to evaluate esophageal motor abnormalities in patients with dysphagia, chest pain, or reflux symptoms. Although manometry is the gold standard for evaluation of these symptoms, patients with dysphagia often have normal results in manometry studies. Aim The objective of this work was to test the hypothesis that challenging the esophagus with viscous apple sauce boluses uncovers motor abnormalities in patients with dysphagia not seen when using water swallows. Methods High-resolution esophageal manometry was performed using ten water swallows followed by ten apple sauce swallows in consecutive subjects presenting with dysphagia. Subjects with grossly abnormal water swallow evaluations were excluded. Each swallow was categorized as normal, hypotensive (distal isobaric contour plots of 5 cm), or simultaneous (distal esophageal velocity ≥8.0 cm/s). Ineffective esophageal motility (IEM) was defined as ≥30% hypotensive swallows, and pressurization was defined as ≥20% simultaneous pressure waves. Results Data from 41 subjects was evaluated. Overall, 96.3% of water swallows were normal, 2.9% hypotensive, and 0.7% simultaneous. Only 70.3% of viscous swallows were normal; 16.7% were hypotensive and 13.0% were simultaneous (P < 0.001 all groups). Seven (17.1%) met criteria for IEM, and pressurization with viscous swallows was observed for nine (22.0%). Fourteen subjects (34.1%) had abnormal results from viscous studies. The presence of any abnormal water swallows was predictive of abnormal viscous swallows (OR = 9.00, CI = 2.15–80.0), although the presence of hypotensive or simultaneous water swallows was not associated with IEM (OR = 0.63, CI = 0.16–2.17) or pressurization (OR = 7.00, CI = 0.90–315.4) with viscous apple sauce. Conclusions Apple sauce challenge increased identification of classifiable motor disorders in patients with dysphagia and may be preferred to alternative bolus materials.Keywords
This publication has 21 references indexed in Scilit:
- Normal values for manometry performed with swallows of viscous test materialScandinavian Journal of Gastroenterology, 2008
- Influence of Bolus Consistency and Position on Esophageal High-Resolution Manometry FindingsDigestive Diseases and Sciences, 2007
- Impedance manometry with viscous test solution increases detection of esophageal function defects compared to liquid swallowsScandinavian Journal of Gastroenterology, 2007
- Physiology of the esophageal pressure transition zone: separate contraction waves above and belowAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2006
- High‐resolution manometry predicts the success of oesophageal bolus transport and identifies clinically important abnormalities not detected by conventional manometryNeurogastroenterology & Motility, 2004
- Esophageal function testing with combined multichannel intraluminal impedance and manometry: Multicenter study in healthy volunteersClinical Gastroenterology and Hepatology, 2003
- Esophageal function testing with combined multichannel intraluminal impedance and manometry: Multicenter study in healthy volunteersClinical Gastroenterology and Hepatology, 2003
- Classification of oesophageal motility abnormalitiesGut, 2001
- Solid swallowing versus water swallowing: manometric study of dysphagiaDigestive Diseases and Sciences, 1992
- Systematic comparison of conventional oesophageal manometry with oesophageal motility while eating bread.Gut, 1991