Self-contamination during doffing of personal protective equipment by healthcare workers to prevent Ebola transmission
Authors:
- Lorna K. P. SuenLSLorna K. P. Suen
- Yue Ping GuoYGYue Ping Guo
- Danny W. K. TongDTDanny W. K. Tong
- Polly H. M. LeungPLPolly H. M. Leung
- David LungDLDavid Lung
- Mandy S. P. NgMNMandy S. P. Ng
- Timothy K. H. LaiTLTimothy K. H. Lai
- Kiki Y. K. LoKLKiki Y. K. Lo
- Cypher H. Au-YeungCACypher H. Au-Yeung
- Winnie YuWYWinnie Yu
Open Access
- 22 December 2018
- journal article
- research article
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
- Vol. 7 (1) , 1-9
Abstract
Background: Healthcare workers (HCWs) use personal protective equipment (PPE) in Ebola virus disease (EVD) situations. However, preventing the contamination of HCWs and the environment during PPE removal crucially requires improved strategies. This study aimed to compare the efficacy of three PPE ensembles, namely, Hospital Authority (HA) Standard Ebola PPE set (PPE1), Dupont Tyvek Model, style 1422A (PPE2), and HA isolation gown for routine patient care and performing aerosol-generating procedures (PPE3) to prevent EVD transmission by measuring the degree of contamination of HCWs and the environment. Methods: A total of 59 participants randomly performed PPE donning and doffing. The trial consisted of PPE donning, applying fluorescent solution on the PPE surface, PPE doffing of participants, and estimation of the degree of contamination as indicated by the number of fluorescent stains on the working clothes and environment. Protocol deviations during PPE donning and doffing were monitored. Results: PPE2 and PPE3 presented higher contamination risks than PPE1. Environmental contaminations such as those originating from rubbish bin covers, chairs, faucets, and sinks were detected. Procedure deviations were observed during PPE donning and doffing, with PPE1 presenting the lowest overall deviation rate (%) among the three PPE ensembles (p < 0.05). Conclusion: Contamination of the subjects’ working clothes and surrounding environment occurred frequently during PPE doffing. Procedure deviations were observed during PPE donning and doffing. Although PPE1 presented a lower contamination risk than PPE2 and PPE3 during doffing and protocol deviations, the design of PPE1 can still be further improved. Future directions should focus on designing a high-coverage-area PPE with simple ergonomic features and on evaluating the doffing procedure to minimise the risk of recontamination. Regular training for users should be emphasised to minimise protocol deviations, and in turn, guarantee the best protection to HCWs.Keywords
Funding Information
- Hong Kong Polytechnic University (4-ZZFR)
This publication has 19 references indexed in Scilit:
- Use of an ultraviolet tracer in simulation training for the clinical management of Ebola virus diseaseJournal of Hospital Infection, 2015
- Contamination during doffing of personal protective equipment by healthcare providersClinical and Experimental Emergency Medicine, 2015
- Ebola virus disease: The use of fluorescents as markers of contamination for personal protective equipmentIDCases, 2015
- Ebola Virus Disease and the Need for New Personal Protective EquipmentJAMA, 2014
- Environment and body contamination: A comparison of two different removal methods in three types of personal protective clothingAmerican Journal of Infection Control, 2014
- Effect of single- versus double-gloving on virus transfer to health care workers’ skin and clothing during removal of personal protective equipmentAmerican Journal of Infection Control, 2012
- Comparison of hand contamination rates and environmental contamination levels between two different glove removal methods and distancesAmerican Journal of Infection Control, 2011
- Virus Transfer from Personal Protective Equipment to Healthcare Employees’ Skin and ClothingEmerging Infectious Diseases, 2008
- Contamination: a comparison of 2 personal protective systemsCanadian Medical Association Journal, 2006
- Effective personal protective clothing for health care workers attending patients with severe acute respiratory syndromeAmerican Journal of Infection Control, 2004