Validating motor unit firing patterns extracted by EMG signal decomposition
- 2 November 2010
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (6) , 649-658
Abstract
Motor unit (MU) firing pattern information can be used clinically or for physiological investigation. It can also be used to enhance and validate electromyographic (EMG) signal decomposition. However, in all instances the validity of the extracted MU firing patterns must first be determined. Two supervised classifiers that can be used to validate extracted MU firing patterns are proposed. The first classifier, the single/merged classifier (SMC), determines whether a motor unit potential train (MUPT) represents the firings of a single MU or the merged activity of more than one MU. The second classifier, the single/contaminated classifier (SCC), determines whether the estimated number of false-classification errors in a MUPT is acceptable or not. Each classifier was trained using simulated data and tested using simulated and real data. The accuracy of the SMC in categorizing a train correctly is 99% and 96% for simulated and real data, respectively. The accuracy of the SCC is 84% and 81% for simulated and real data, respectively. The composition of these classifiers, their objectives, how they were trained, and the evaluation of their performances using both simulated and real data are presented in detail.Keywords
This publication has 33 references indexed in Scilit:
- From association to classification: inference using weight of evidenceIEEE Transactions on Knowledge and Data Engineering, 2003
- The null distribution of sample serial correlation coefficientStochastic Environmental Research and Risk Assessment, 2002
- Unsupervised pattern recognition for the classification of EMG signalsIEEE Transactions on Biomedical Engineering, 1999
- Multi-MUP EMG analysis — a two year experience in daily clinical workElectroencephalography and Clinical Neurophysiology/Electromyography and Motor Control, 1995
- Floating search methods in feature selectionPattern Recognition Letters, 1994
- NNERVE: Neural Network Extraction of Repetitive Vectors for Electromyography. I. AlgorithmIEEE Transactions on Biomedical Engineering, 1994
- Altered mechanisms of muscular force generation in lower motor neuron diseaseMuscle & Nerve, 1989
- Comparison of the recruitment and discharge properties of motor units in human brachial biceps and adductor pollicis during isometric contractionsBrain Research, 1981
- Impaired regulation of force and firing pattern of single motor units in patients with spasticity.Journal of Neurology, Neurosurgery & Psychiatry, 1980
- Calculation of the electromyographic jitterJournal of Neurology, Neurosurgery & Psychiatry, 1974