Abstract
The purpose of this study was to compare the effectiveness of 1470- and 980-nm lasers with regard to power output, complications, recanalization rates, and treatment response. We prospectively evaluated the effectiveness of endovenous laser ablation (EVLA) in a total of 152 great and small saphenous veins from 96 patients. Lasers were randomly used based on the availability of the units. Patients were clinically evaluated for Clinical Etiologic Anatomic Pathophysiologic (CEAP) stage and examined with Doppler ultrasound. Treatment response was determined anatomically by occlusion of the vein and clinically by the change in the venous clinical severity score (VCSS). Seventy-eight of the saphenous veins underwent EVLA with a 980-nm laser and 74 underwent EVLA with a 1470-nm laser. Treatment response was (68) 87.2 % in the 980-nm group and (74) 100 % in the 1470-nm group (p = 0.004). The median VCSS decreased from 4 to 2 in the 980-nm group (p < 0.001) and from 8 to 2 (p < 0.001) in the 1470-nm group. At 1-year follow-up, seven veins treated with 980 nm and two veins treated with 1470 nm were recanalized (p = 0.16); the average linear endovenous energy density (LEED) was 83.9 (r, 55–100) J/cm and 58.5 (r, 45–115) J/cm, respectively (p < 0.001). Postoperative minor complications occurred in 23 (29.4 %) limbs in the 980-nm group and in 19 (25.6 %) limbs of the 1470-nm group (p = 0.73). EVLA with the 1470-nm laser have less energy deposition for occlusion and better treatment response.Keywords
This publication has 22 references indexed in Scilit:
- Concerning the publication: “Histological difference between pulsed wave laser and continuous wave laser in endovenous laser ablation” by Kansaku R, Sakakibara N, Amano A, Endo H, Shimabukuro T, Sueishi M. Phlebology 2015; 30: 429–434Phlebology: The Journal of Venous Disease, 2015
- Temperature profiles of 980- and 1,470-nm endovenous laser ablation, endovenous radiofrequency ablation and endovenous steam ablationLasers in Medical Science, 2013
- Comparing cold and warm tumescent anesthesia for pain perception during and after the endovenous laser ablation procedure with 1470 nm diode laserPhlebology: The Journal of Venous Disease, 2013
- Endovenous 1470 nm laser treatment of the saphenous vein: early report of pain assessment.2013
- The effect of laser wavelength on postoperative pain score in the endovenous ablation of saphenous vein insufficiencyDiagnostic and Interventional Radiology, 2013
- Endoluminal laser delivery mode and wavelength effects on varicose veins in anEx vivomodelLasers in Surgery and Medicine, 2013
- Early clinical improvement in chronic venous insufficiency symptoms after laser ablation of saphenous veinsDiagnostic and Interventional Radiology, 2012
- Sonographic anatomy of the lower extremity superficial veinsDiagnostic and Interventional Radiology, 2011
- Randomized clinical trial of VNUS® ClosureFAST™ radiofrequency ablation versus laser for varicose veinsBritish Journal of Surgery, 2010