Intraoperative Ultrasound for Extracting Deep-Seated Radio-Opaque Foreign Body from Calf
- 1 October 2023
- journal article
- research article
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 13 (4)
Abstract
Case: A 50-year-old man presented with chronic refractory symptoms of radiating leg pain with muscle cramps because of a retained bullet in the calf after being shot in 1990. Radiographs confirmed the bullet lodged in posterolateral aspect of calf abutting proximal fibula. An intraoperative point-of-care ultrasound aided in accurate localization of bullet, thereby facilitating precise planning of surgical incision and subsequent removal. Conclusions: Ultrasound can be used as an alternative tool for safe surgical extraction of deep-seated metallic object with minimal tissue dissection, obviating the need for C-arm.Keywords
This publication has 13 references indexed in Scilit:
- US-guided Localization and Removal of Soft-Tissue Foreign BodiesRadioGraphics, 2020
- Ultrasonography of subcutaneous foreign bodies: differences depending on their nature, complications, and potential diagnostic errorsRadiología (English Edition), 2020
- Orthopaedic residents demonstrate retention of point of care ultrasound knowledge after a brief educational session: a quasi experimental studyBMC Medical Education, 2019
- Application of intraoperative navigation and positioning system in the removal of deep foreign bodies in the limbsChinese Medical Journal, 2019
- Relevance of intraoperative ultrasound imaging for detecting foreign bodies in the hand: A series of 19 casesHand Surgery and Rehabilitation, 2018
- Tracking Cumulative Radiation Exposure in Orthopaedic Surgeons and ResidentsJournal of Bone and Joint Surgery, 2017
- Learning Curves in Emergency Ultrasound EducationAcademic Emergency Medicine, 2015
- Removal of metallic foreign bodies embedded in soft tissues by stereotaxic approachAfrican Health Sciences, 2014
- Current trends in the management of intraocular foreign bodiesCurrent Opinion in Ophthalmology, 2008
- Ultrasound Guided Removal of an Intracranial Bullet: Case ReportAustralasian Radiology, 1986