Experimental Study of Detectable Sizes of Surface Flaws on Copper Tubes by Nondestructive Inspection Using High-Tc Superconducting Quantum Interference Device
- 1 September 2006
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 45 (9L) , L980-983
Abstract
Detectable sizes of shallow flaws on thin copper tubes were experimentally investigated using an eddy-current-based nondestructive inspection system with a high-Tc superconducting quantum interference device (SQUID) gradiometer. At an excitation field of 5.6 µT at 3 kHz, a magnetic anomaly due to the shallowest flaw of 10 µm depth, 100 µm width, and 15 mm length on the surface of a tube specimen of 6.35 mm outer diameter and 0.8 mm thickness was successfully measured. Signal amplitude due to a flaw was proportional to effective flaw volume that made an induced eddy current detour. The experimental results indicate that the detectable volume of a surface flaw on a copper tube should be 1×106 µm3 with some increase in signal-to-noise ratio.Keywords
This publication has 3 references indexed in Scilit:
- SQUID NDE forin situinspection of copper heat exchanger tubesSuperconductor Science and Technology, 2006
- Detection of micro-flaws on thin copper tubes using SQUID-NDI system based on eddy current techniquePhysica C: Superconductivity and its Applications, 2005
- Eddy-Current-Based Nondestructive Inspection System Using Superconducting Quantum Interference Device for Thin Copper TubesJapanese Journal of Applied Physics, 2004