Measurement of laser induced fluorescence for argon plasma flow with oxygen injection
Open Access
- 1 July 2023
- journal article
- research article
- Published by AIP Publishing in AIP Advances
- Vol. 13 (7)
Abstract
The experimental investigation of the effects of O2 injection on the magnetized Ar plasma flow in the linear plasma device was conducted by using the measurement of laser induced fluorescence (LIF) with electric probes. The LIF measurement was based on the Ar ion transition from the 3d4F7/2 metastable level to the 4p4D5/2 level at a wavelength of 668.61 nm. In addition, the analysis of ion velocity distribution functions (IVDFs) involved the detection of fluorescence light emitted from the 4p4D5/2 level to the 4s4P3/2 level, which had a wavelength of 442.72 nm. For a comprehensive analysis of the intricate interaction between O2 injection and the behavior of the Ar plasma flow, the oxygen was injected into the Ar plasma, and the O2/Ar ratio ranged from 0% to 14% while maintaining a constant pressure of 2 mTorr. The Zeeman splitting in the IVDFs was clearly observable for pure Ar plasma due to 800 G as the high magnetic field strength. The split form disappeared due to a small amount of oxygen injected as the O2/Ar ratio of 3.5%. The LIF intensity is in agreement with the tendency of plasma density due to the reduction of Ar ions by charge transfer, quenching, and neutralization as O2 is injected into the Ar plasma. The experimental results show that the effects on temperature and flow velocity for the Ar ions are insignificant when O2 is injected into the Ar plasma at the O2/Ar ratio of 0%–14%, in contrast to the large change in the electron temperature.Keywords
Funding Information
- National Research Council of Science and Technology (CAP22021-200)
- Korea Institute of Fusion Energy (EN2321-11)
This publication has 30 references indexed in Scilit:
- Active species downstream of an Ar–O2surface-wave microwave discharge for biomedicine, surface treatment and nanostructuringPlasma Sources Science and Technology, 2011
- A study of the plasma electronegativity in an argon–oxygen pulsed-dc sputter magnetronJournal of Physics D: Applied Physics, 2010
- Effect of ion–neutral collision on the deduction of Mach number in collisional plasmasJournal of Physics D: Applied Physics, 2009
- One- and two-dimensional laser induced fluorescence at oblique incidencePlasma Sources Science and Technology, 2009
- Deduction of the absolute negative ion density by using planar and cylindrical electric probes simultaneouslyPhysics of Plasmas, 2006
- Electric Probe Systems for Diversified Plasma Simulator (DiPS)Contributions to Plasma Physics, 2006
- Comparative studies of the laser Thomson scattering and Langmuir probe methods for measurements of negative ion density in a glow discharge plasmaPlasma Sources Science and Technology, 2003
- Experimental Studies of the Bohm Criterion in a Two-Ion-Species Plasma Using Laser-Induced FluorescencePhysical Review Letters, 2003
- Plasma chemistry and surface processes of negative ionsPlasma Sources Science and Technology, 2001
- Information from probe characteristics in negative ion containing plasmaJournal of Applied Physics, 1998