Agreement and Repeatability of Corneal Thickness and Radius among Three Different Corneal Measurement Devices
Authors:
- 1 October 2021
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (10) , 1196-1202
Abstract
SIGNIFICANCE: Corneal refractive surgery screening, orthokeratology, and contact lens fitting require accurate estimation of the corneal thickness and curvature. We found that any of the imaging devices used in this study can be used to image a healthy myopic cornea, which is essential to screen for corneal ectasia. PURPOSE: This study aimed to compare agreement and repeatability of corneal thickness and radius measurements obtained using Scheimpflug imaging (Pentacam HR), swept‐source optical coherence tomography (Casia SS‐1000), and Placido‐Scheimpflug tomography (Topographic Modeling System, version 5 [TMS‐5]). METHODS: Sixty eyes of 60 subjects with myopia were measured with Casia, TMS‐5, and Pentacam for their central corneal thickness (CCT), thinnest corneal thickness, central corneal radius of the steep meridian (Ks), central corneal radius of the flat meridian (Kf), mean central corneal radius (Km), and anterior and posterior best‐fit spheres. Two readings were obtained from each instrument. Central corneal thickness was also measured with ultrasound pachymetry. Intraclass correlation coefficient, repeatability coefficient, and coefficient of variation were calculated. RESULTS: Repeatability coefficient, coefficient of variation, and intraclass correlation coefficient of CCT among the instruments ranged between 2.48 and 12.79, 0.17 and 0.86, and 0.98 and 1.00, respectively. Mean CCT measurements were similar between Casia, TMS‐5, Pentacam, and ultrasound pachymetry ( P = . 13). Intraclass range of correlation for agreement was 0.95 to 0.99 for CCT among instruments. The range of 95% limits of agreement (LoAs) for ultrasound CCT was narrowest with Casia (31.94 μm). Casia–TMS‐5 displayed a narrow range of 95% LoA for CCT (12.14 to −12.44), thinnest corneal thickness (12.31 to −11.31), and Ks (0.56 to −0.53), whereas Casia‐Pentacam showed a narrow range of 95% LoA for Kf (0.56 to −0.42), Km (0.41 to −0.27), and anterior best‐fit sphere (0.03 to −0.07). A significant difference in posterior best‐fit sphere measurements was noted among all instruments ( P =. 01). CONCLUSIONS: Casia, TMS‐5, and Pentacam can be used interchangeably to measure corneal thickness and radius measurement in healthy eyes. Casia had the best agreement with ultrasound pachymeter CCT and exhibited the highest repeatability.Keywords
This publication has 27 references indexed in Scilit:
- Scheimpflug imaging for keratoconus and ectatic diseaseIndian Journal Of Ophthalmology, 2013
- Corneal thickness, curvature, and elevation readings in normal corneas: Combined Placido–Scheimpflug system versus combined Placido–scanning-slit systemJournal of Cataract & Refractive Surgery, 2012
- Comparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographerJournal of Cataract & Refractive Surgery, 2011
- Corneal topography with high-speed swept source OCT in clinical examinationBiomedical Optics Express, 2011
- A Comprehensive Comparison of Central Corneal Thickness MeasurementOptometry and Vision Science, 2011
- Corneal imaging with slit‐scanning and Scheimpflug imaging techniquesClinical and Experimental Optometry, 2011
- Imaging of the Cornea: Topography vs TomographyJournal of Refractive Surgery, 2010
- Comparison of Pentacam and Orbscan IIz on Posterior Curvature Topography Measurements in Keratoconus EyesOphthalmology, 2006
- Assessing the accuracy of Orbscan II post‐LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful proceduresClinical & Experimental Ophthalmology, 2005
- Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusisBritish Journal of Ophthalmology, 2004