Time-Dependent Phenomena in the Potential Response of Ion-selective Electrodes Treated by the Nernst−Planck−Poisson Model. 1. Intramembrane Processes and Selectivity
- 8 September 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (19) , 6783-6791
Abstract
The variability of selectivity coefficients, resulting from potential changes over time and the concentration ratio of primary to interfering ions, impedes many practical applications of ion-selective electrodes (ISEs). Existing theoretical interpretations of ISE selectivity are restricted by severe assumptions, such as steady state and electroneutrality, which hinder theorizing on this problem. For this reason, for the first time, the Nernst−Planck−Poisson equations are used to predict and visualize the selectivity variability over time and the concentration ratio. Special emphasis is placed on the non-Nernstian response in the measurements with liquid-ion-exchanger- and neutral-carrier-based ISEs. The conditions under which measured selectivity coefficients are true (unbiased) are demonstrated.Keywords
This publication has 26 references indexed in Scilit:
- Application of Nernst–Planck and Poisson equations for interpretation of liquid-junction and membrane potentials in real-time and space domainsElectrochemistry Communications, 2001
- Potentiometric Selectivity Coefficients of Ion-Selective Electrodes. Part I. Inorganic Cations (Technical Report)Pure and Applied Chemistry, 2000
- Improvement of potentiometric selectivity of ion-exchanger based membranes doped with co-exchanger: Origin of the effectSensors and Actuators B: Chemical, 1998
- Selectivity of carrier-based ion-selective electrodes: is the problem solved?TrAC Trends in Analytical Chemistry, 1997
- Behavior of cations in nonsuppressed anion chromatographyAnalytical Chemistry, 1983
- Determination of selectivity coefficients of ion-selective electrodes by means of linearized multiple standard addition techniquesAnalytica Chimica Acta, 1983
- Potentiostat with a positive feedback IR compensation and a high sensitivity current follower indicator circuit for direct determination of high second-order rate constantsAnalytical Chemistry, 1982
- Interpretation of selectivity coefficients of solid-state ion-selective electrodes by means of the diffusion-layer modelTalanta, 1977
- Selectivity coefficient changes for liquid-membrane electrodesAnalytica Chimica Acta, 1975
- Selectivity ratios/coefficients of selective ion sensitive electrodesTalanta, 1971