Fabrication of Nonenzymatic Glucose Sensors Based on Multiwalled Carbon Nanotubes with Bimetallic Pt-M (M = Ru and Sn) Catalysts by Radiolytic Deposition
Authors:
Open Access
- 1 January 2012
- journal article
- research article
- Published by Wiley in Journal of Sensors
- Vol. 2012, 1-8
Abstract
Nonenzymatic glucose sensors employing multiwalled carbon nanotubes (MWNTs) with highly dispersed Pt-M (M = Ru and Sn) nanoparticles (Pt-M@PVP-MWNTs) were fabricated by radiolytic deposition. The Pt-M nanoparticles on the MWNTs were characterized by transmittance electron microscopy, elemental analysis, and X-ray diffraction. They were found to be well dispersed and to exhibit alloy properties on the MWNT support. Electrochemical testing showed that these nonenzymatic sensors had larger currents (mA) than that of a bare glassy carbon (GC) electrode and one modified with MWNTs. The sensitivity (A mM−1), linear range (mM), and detection limit (mM) (S/N = 3) of the glucose sensor with the Pt-Ru catalyst in NaOH electrolyte were determined as 18.0, 1.0–2.5, 0.7, respectively. The corresponding data of the sensor with Pt-Sn catalyst were 889.0, 1.00–3.00, and 0.3, respectively. In addition, these non-enzymatic sensors can effectively avoid interference arising from the oxidation of the common interfering species ascorbic acid and uric acid in NaOH electrolyte. The experimental results show that such sensors can be applied in the detection of glucose in commercial red wine samples.Keywords
Funding Information
- National Research Foundation (2010-013-1-C00023, 2010-0019129)
- National Research Foundation (2010-013-1-C00023, 2010-0019129)
This publication has 36 references indexed in Scilit:
- Immobilization and direct electrochemistry of glucose oxidase on a tetragonal pyramid-shaped porous ZnO nanostructure for a glucose biosensorBiosensors and Bioelectronics, 2009
- Development of a disposable glucose biosensor using electroless-plated Au/Ni/copper low electrical resistance electrodesBiosensors and Bioelectronics, 2008
- Pt–Pb alloy nanoparticle/carbon nanotube nanocomposite: a strong electrocatalyst for glucose oxidationNanotechnology, 2006
- Platinum nanoparticles-doped sol–gel/carbon nanotubes composite electrochemical sensors and biosensorsBiosensors and Bioelectronics, 2006
- Home blood glucose biosensors: a commercial perspectiveBiosensors and Bioelectronics, 2005
- Nonenzymatic Glucose Detection by Using a Three‐Dimensionally Ordered, Macroporous Platinum TemplateChemistry – A European Journal, 2005
- Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titania sol–gel membraneBiosensors and Bioelectronics, 2003
- Fabrication of glucose oxidase/polypyrrole biosensor by galvanostatic method in various pH aqueous solutionsBiosensors and Bioelectronics, 2003
- Nonenzymatic Glucose Detection Using Mesoporous PlatinumAnalytical Chemistry, 2003
- Amperometric Glucose Biosensor Based on Sol−Gel Organic−Inorganic Hybrid MaterialAnalytical Chemistry, 1998