Optimal Determination of the Truncation Point of Room Impulse Responses
Authors:
- 1 January 2005
- journal article
- Published by SAGE Publications in Building Acoustics
- Vol. 12 (1) , 15-29
Abstract
A theoretically obtained optimal Truncation Point (TP) in the Room Impulse Response (RIR) is located at the intersection of the main decay slope and the noise floor. Precise determination of this point is difficult in practice. Namely, the deviation of the RIR decay from the exponential decay can lead to discrepancies in the determined TP from the optimal value. In order to increase the accuracy of TP determination, additional terms are incorporated in a simple algorithm. Besides, iterative algorithm for RIR truncation is proposed. These are compared with the existing one, using simulated and measured RIRs. The results confirm the validity of the proposed algorithms, indicating their advantages. In addition, the influences of the response parameters on RIR truncation are investigated.Keywords
This publication has 6 references indexed in Scilit:
- Inaccuracies in sound pressure level determination from room impulse responseThe Journal of the Acoustical Society of America, 2002
- A parametric error analysis of the backward integration method for reverberation time estimationThe Journal of the Acoustical Society of America, 1997
- Objective measures of listener envelopmentThe Journal of the Acoustical Society of America, 1995
- Evaluation of reverberation times using a nonlinear regression approachThe Journal of the Acoustical Society of America, 1995
- Comparison of reverberation measurements using Schroeder’s impulse method and decay-curve averaging methodThe Journal of the Acoustical Society of America, 1978
- New Method of Measuring Reverberation TimeThe Journal of the Acoustical Society of America, 1965