Polyethylene glycol antiglobulin tube versus gel microcolumn: influence on the incidence of delayed hemolytic transfusion reactions and delayed serologic transfusion reactions
- 1 July 2010
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 50 (7) , 1444-1452
Abstract
BACKGROUND: Our institution has reported on delayed hemolytic transfusion reaction (DHTR) and delayed serologic transfusion reaction (DSTR) incidence changes. From January 1993 to June 2003, a polyethylene glycol (PEG) tube–based technique was used for red blood cell (RBC) antibody screen. In June 2003, a gel microcolumn technique was implemented. Impact of this on antibody detection and DHTR and DSTR incidence was investigated.STUDY DESIGN AND METHODS: Positive antibody screen frequency and antibody specificity from January 2002 to March 2003 and July 2003 to September 2004 were compared. Overall incidence of DHTR and DSTR as well as the number and identity of the RBC antibodies implicated from August 1999 through June 2003 (PEG) and July 2003 through July 2007 (gel) were compared. The mean length of hospital stay (LOS) and number of RBC units transfused per patient were compared.RESULTS: Equivalent numbers of antibody screens were performed with equivalent numbers of positive screens. Significant differences were not seen in the detection of clinically significant antibodies but significantly fewer clinically insignificant antibodies were detected with gel. Ninety‐six DHTRs and DSTRs were diagnosed. The LOS and number of transfused RBC units were not statistically different. A significantly higher incidence of DHTRs and DSTRs was seen with PEG compared to the gel.CONCLUSION: The gel microcolumn method is similar to the PEG in detecting clinically significant antibodies but detects fewer clinically insignificant antibodies. The implementation of gel resulted in a lower incidence of DHTRs and DSTRs compared to PEG.Keywords
This publication has 11 references indexed in Scilit:
- In search of the Holy Grail: comparison of antibody screening methodsImmunohematology, 2006
- Comparison of tube and gel techniques for antibody identificationImmunohematology, 2000
- Trends in the incidence of delayed hemolytic and delayed serologic transfusion reactionsTransfusion, 1999
- The gel test: use in the identification of unexpected antibodies to blood group antigensImmunohematology, 1998
- The differentiation of delayed hemolytic and delayed serologic transfusion reactions: incidence and predictors of hemolysisTransfusion, 1995
- The differentiation of delayed serologic and delayed hemolytic transfusion reactions: incidence, long‐term serologic findings, and clinical significanceTransfusion, 1990
- The gel test: a new way to detect red cell antigen‐antibody reactionsTransfusion, 1990
- Polyethylene Glycol: A New Potentiator of Red Blood Cell Antigen–Antibody ReactionsAmerican Journal of Clinical Pathology, 1987
- Delayed Hemolytic Transfusion Reactions. Evidence of the Need for an Improved Pretransfusion Compatibility TestAmerican Journal of Clinical Pathology, 1980
- Delayed Hemolytic Transfusion ReactionTransfusion, 1978