An Automated Hydrodynamically Mediated Technique for Preparation of Calibration Solutions via Capillary Electrophoresis System as a Promising Alternative to Manual Pipetting
Open Access
Abstract
In this paper, a novel procedure for preparing calibration solutions for capillary electrophoresis (CE)-based quantitative analysis is proposed. Our approach, named the automated hydrodynamically mediated technique (AHMT), uses a capillary and a pressure system to deliver the expected amount of working solution and diluent directly to a sample vial. As a result, calibration solutions are prepared automatically inside the CE instrument, without any or with minimal manual operation. Two different modes were tested: forward and reverse, differing in the direction of hydrodynamic flow. The calibration curves obtained for a model mixture of analytes using AHMT were thorough compared to the standard procedure based on manual pipetting. The results were consistent, though the volume of obtained calibration solutions and the potential risk of random errors were significantly minimized by AHMT. Its effectiveness was further enhanced by the application of SCIEX® nanoVials, reducing the actual volume of calibration solutions down to 10 μL.Keywords
Funding Information
- International Visegrad Fund (21930006)
This publication has 15 references indexed in Scilit:
- Flow variation as a factor determining repeatability of the internal standard-based qualitative and quantitative analyses by capillary electrophoresisJournal of Chromatography A, 2018
- An automated continuous homogeneous microextraction for the determination of selenium and arsenic by hydride generation atomic fluorescence spectrometryTalanta, 2018
- Flow chemistry vs. flow analysisTalanta, 2016
- Analytical strategies for coupling separation and flow-injection techniquesTrAC Trends in Analytical Chemistry, 2015
- Green Analytical ChemistryTrAC Trends in Analytical Chemistry, 2008
- Automated sample preparation and analysis using a sequential-injection–capillary electrophoresis (SI–CE) interfaceThe Analyst, 2006
- Automatic calibration in capillary electrophoresisElectrophoresis, 2000
- General Deming Regression for Estimating Systematic Bias and Its Confidence Interval in Method-Comparison StudiesClinical Chemistry, 2000
- Performance of Deming regression analysis in case of misspecified analytical error ratio in method comparison studiesClinical Chemistry, 1998
- Automatic calibration in continuous flow analysisAnalytica Chimica Acta, 1996