A robust method for automated background subtraction of tissue fluorescence
- 14 May 2007
- journal article
- research article
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 38 (9) , 1199-1205
Abstract
This paper introduces a new robust method for the removal of background tissue fluorescence from Raman spectra. Raman spectra consist of noise, fluorescence and Raman scattering. In order to extract the Raman scattering, both noise and background fluorescence must be removed, ideally without human intervention and preserving the original data. We describe the rationale behind our robust background subtraction method, determine the parameters of the method and validate it using a Raman phantom against other methods currently used. We also statistically compare the methods using the residual mean square (RMS) with a fluorescence‐to‐signal (F/S) ratio ranging from 0.1 to 1000. The method, ‘adaptive minmax’, chooses the subtraction method based on the F/S ratio. It uses multiple fits of different orders to maximize each polynomial fit. The results show that the adaptive minmax method was significantly better than any single polynomial fit across all F/S ratios. This method can be implemented as part of a modular automated real‐time diagnostic in vivo Raman system. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 16 references indexed in Scilit:
- In vivo Margin Assessment during Partial Mastectomy Breast Surgery Using Raman SpectroscopyCancer Research, 2006
- Fiber-Optic Probes for in Vivo Raman Spectroscopy in the High-Wavenumber RegionAnalytical Chemistry, 2005
- Investigation of Selected Baseline Removal Techniques as Candidates for Automated ImplementationApplied Spectroscopy, 2005
- Near‐infrared Raman spectroscopy for optical diagnosis of lung cancerInternational Journal of Cancer, 2003
- Raman microspectroscopic model of human breast tissue: implications for breast cancer diagnosis in vivoJournal of Raman Spectroscopy, 2002
- Real‐time tissue characterization on the basis of in vivo Raman spectraJournal of Raman Spectroscopy, 2002
- Curve Fitting and Linearity: Data Processing in Raman SpectroscopyApplied Spectroscopy, 2001
- Near-Infrared Raman Spectrometer Systems for Human Tissue StudiesApplied Spectroscopy, 1997
- Effective Rejection of Fluorescence Interference in Raman Spectroscopy Using a Shifted Excitation Difference TechniqueApplied Spectroscopy, 1992
- Computer-controlled instrument for the recovery of a resonance Raman spectrum in the presence of strong luminescenceAnalytical Chemistry, 1984