Comparison of State Estimators for a Permanent Magnet Synchronous Generator
- 1 October 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 474-479
Abstract
A Permanent Magnet Synchronous Generator is chosen as a case study for this comparison. A continous model with a discrete integrator is shown to be the best solution for the discretization of the nonlinear model. Then, the Kalman Filter (KF), the Extended Kalman Filter (EKF) and the Unscented Kalman Filter are compared. The results are presented and it is shown that the EKF is the best suited for this application. Moreover, a discussion regarding the behaviour of the filters follows, where all are shown to act like proportional controllers.Keywords
This publication has 7 references indexed in Scilit:
- Do the Cubature and Unscented Kalman Filtering Methods Outperform Always the Extended Kalman Filter ?IFAC-PapersOnLine, 2017
- Innovations in fault detection and tolerant control for a wind farm, using Wireless Sensor Networks2017
- Dynamic state estimation of a permanent magnet synchronous generator‐based wind turbineIET Renewable Power Generation, 2016
- Vibration-based Fault Diagnosis Approach for Permanent Magnet Synchronous MotorsIFAC-PapersOnLine, 2015
- A Sensor Fault Detection and Isolation Method in Interior Permanent-Magnet Synchronous Motor Drives Based on an Extended Kalman FilterIEEE Transactions on Industrial Electronics, 2013
- A Comparative Study of Predictive Current Control Schemes for a Permanent-Magnet Synchronous Machine DriveIEEE Transactions on Industrial Electronics, 2009
- The square-root unscented Kalman filter for state and parameter-estimation2002