Cobinamide-Based Cyanide Analysis by Multiwavelength Spectrometry in a Liquid Core Waveguide
Authors:
- Purnendu K. DasguptaPDPurnendu K. Dasgupta
- William BlackledgeWBWilliam Blackledge
- Gerry R. BossGBGerry R. Boss
- 18 June 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (14) , 6244-6250
Abstract
A novel cyanide analyzer based on sensitive cobinamide chemistry relies on simultaneous reagent and sample injection and detection in a 50 cm liquid core waveguide (LCW) flow cell illuminated by a white light emitting diode. The transmitted light is read by a fiber-optic charge coupled device (CCD) spectrometer. Alkaline cobinamide (orange, λmax = 510 nm) changes to violet (λmax = 583 nm) upon reaction with cyanide. Multiwavelength detection permits built-in correction for artifact responses intrinsic to a single-line flow injection system and corrects for drift. With optimum choice of the reaction medium, flow rate, and mixing coil length, the limit of detection (LOD, S/N = 3) is 30 nM and the linear dynamic range extends to 10 μM. The response base width for 1% carryover is n = 5), 3.2% (n = 7), and 1.7% (n = 6), respectively. Common ions at 250−80 000× concentrations do not interfere except for sulfide. For the determination of 2 μM CN−, the presence of 2, 5, 10, 20, 100, and 1000 μM HS− results in 22, 27, 48, 58, 88, and 154% overestimation of cyanide. The sulfide product actually has a different characteristic absorption, and in those samples where significant presence is likely, this can be corrected for. We demonstrate applicability by analyzing the hydrolytic cyanide extract of apple and pear seeds with orange seeds as control and also measure HCN in breath air samples. Spike recoveries in these sample extracts ranged from 91 to 108%.Keywords
This publication has 38 references indexed in Scilit:
- Recent developments in cyanide detection: A reviewAnalytica Chimica Acta, 2010
- New Facile Method to Measure Cyanide in BloodAnalytical Chemistry, 2010
- Temperature Dependence of Henry’s Law Constant for Hydrogen Cyanide. Generation of Trace Standard Gaseous Hydrogen CyanideEnvironmental Science & Technology, 2010
- The development of an electrochemical sensor for the determination of cyanide in physiological solutionsAnalytica Chimica Acta, 2006
- Determination of acetone in breathAnalytica Chimica Acta, 2005
- Analytical techniques for cyanide in blood and published blood cyanide concentrations from healthy subjects and fire victimsAnalytica Chimica Acta, 2004
- Light emitting diode-based detectorsAnalytica Chimica Acta, 2003
- Portable flow-injection analyzer with liquid-core waveguide based fluorescence, luminescence, and long path length absorbance detectorAnalytica Chimica Acta, 2003
- Selective determination of gases by two-stage membrane-differentiated flow injection analysis. Determination of trace hydrogen cyanide in the presence of large concentrations of hydrogen sulfideAnalytical Chemistry, 1992
- Double-injection flow injection analysis using multivariate calibration for multicomponent analysisAnalytical Chemistry, 1991