A Lower-Back Exoskeleton With a Four-Bar Linkage Structure for Providing Extensor Moment and Lumbar Traction Force
Open Access
- 14 March 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 729-737
Abstract
Lower back pain and related injuries are prevalent and serious problems in various industries, and high compression force to the lumbosacral (L5/S1) region has been known as one of the key factors. Previous research on passive lower back exoskeletons focused on reducing lumbar muscle activation by providing an extensor moment. Additionally, lumbar traction forces can reduce the compression force, and is a common treatment method for lower back pain in clinics. In this paper, we propose a novel passive lower back exoskeleton that provides both extensor moment and lumbar traction force. The working principle of the exoskeleton, extending the coil springs during lumbar flexion, and its design criteria regarding the amount of each force element were provided. The kinematic model explained its operation, and the dynamic simulation estimated its performance and validated its satisfaction with the design criteria. The biomechanical model provided a brief insight into the expected exoskeleton’s effect on the reduced lower back compression force. Ten subjects performed static holding and dynamic lifting tasks, and the generated force elements in two directions, parallel and perpendicular to the trunk, were evaluated using a force sensor and electromyography sensors, respectively. The experiment demonstrated a pulling force opposite to the direction of intradiscal pressure and reduced erector spinae activation. This implies the effect of wearing the exoskeleton to decrease the intervertebral pressure during static back bending or heavy lifting tasks.Keywords
Funding Information
- Korea Evaluation Institute of Industrial Technology (20010776)
- Korea Agency for Infrastructure Technology Advancement (21CTAP-C158002-01)
This publication has 52 references indexed in Scilit:
- A Literature Review of Ergonomics Risk Factors in Construction IndustryProcedia Engineering, 2011
- PLAD (personal lift assistive device) stiffness affects the lumbar flexion/extension moment and the posterior chain EMG during symmetrical lifting tasksJournal of Electromyography and Kinesiology, 2009
- Understanding the ergonomic risk for musculoskeletal disorders in the United States agricultural sectorAmerican Journal of Industrial Medicine, 2007
- Mathematical and empirical proof of principle for an on-body personal lift augmentation device (PLAD)Journal of Biomechanics, 2007
- Active trunk stiffness increases with co-contractionJournal of Electromyography and Kinesiology, 2006
- Stabilizing Function of Trunk Flexor-Extensor Muscles Around a Neutral Spine PostureSpine, 1997
- Revised NIOSH equation for the design and evaluation of manual lifting tasksErgonomics, 1993
- A biomechanical model of the lumbosacral joint during lifting activitiesJournal of Biomechanics, 1985
- Epidemiologic Aspects on Low-Back Pain in IndustrySpine, 1981
- A computerized biomechanical model—Development of and use in studying gross body actionsJournal of Biomechanics, 1969