Introduction: This study describes quality indicators for the pre-analytical process, grouping errors according to patient risk as critical or major, and assesses their evaluation over a five-year period. Materials and methods: A descriptive study was made of the temporal evolution of quality indicators, with a study population of 751,441 analytical requests made during the period 2007-2011. The Runs Test for randomness was calculated to assess changes in the trend of the series, and the degree of control over the process was estimated by the Six Sigma scale. Results: The overall rate of critical pre-analytical errors was 0.047%, with a Six Sigma value of 4.9. The total rate of sampling errors in the study period was 13.54% (P = 0.003). The highest rates were found for the indicators “haemolysed sample” (8.76%), “urine sample not submitted” (1.66%) and “clotted sample” (1.41%), with Six Sigma values of 3.7, 3.7 and 2.9, respectively. Conclusions: The magnitude of pre-analytical errors was accurately valued. While processes that triggered critical errors are well controlled, the results obtained for those regarding specimen collection are borderline unacceptable; this is particularly so for the indicator “haemolysed sample”. Key words: total quality management; quality indicators, health care; laboratories; patient safetyKeywords
This publication has 19 references indexed in Scilit:
- Exploring the Initial Steps of the Testing Process: Frequency and Nature of Pre-Preanalytic ErrorsClinical Chemistry, 2012
- Causes, consequences, detection, and prevention of identification errors in laboratory diagnosticsClinical Chemistry and Laboratory Medicine (CCLM), 2008
- Errors in a Stat Laboratory: Types and Frequencies 10 Years LaterClinical Chemistry, 2007
- How can we make laboratory testing safer?Clinical Chemistry and Laboratory Medicine (CCLM), 2007
- Application of the Six Sigma concept in clinical laboratories: a reviewClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors.Archives of Pathology & Laboratory Medicine, 2006
- Preanalytic Error Tracking in a Laboratory Medicine Department: Results of a 1-Year ExperienceClinical Chemistry, 2006
- Laboratory network of excellence: enhancing patient safety and service effectivenessClinical Chemistry and Laboratory Medicine (CCLM), 2006
- Quality indicators and specifications for the extra-analytical phases in clinical laboratory managementClinical Chemistry and Laboratory Medicine (CCLM), 2004
- Mistakes in a stat laboratory: types and frequencyClinical Chemistry, 1997