Coupling Strong Anion-Exchange Monolithic Capillary with MALDI-TOF MS for Sensitive Detection of Phosphopeptides in Protein Digest
- 3 March 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (7) , 2907-2915
Abstract
Protein phosphorylation is one of the most biologically relevant and ubiquitous post-translational modifications. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a powerful tool for the analysis of protein phosphorylation by detection of phosphopeptides in phosphoprotein digest. Enrichment of phosphopeptides by immobilized metal ion affinity chromatography (IMAC) or metal oxide affinity chromatography (MOAC) followed with MALDI analysis is the common approach. However, the pH for loading and elution of phosphopeptides is incompatible with protein digestion as well as the preparation of the MALDI matrix solution. Therefore, some pretreatment steps, such as pH adjustment and desalting, are required, which make the approach tedious and insensitive. In this study, a strong anion-exchange (SAX) capillary monolith was prepared to enrich phosphopeptides from protein digest for MALDI-TOF MS analysis. It was found that phosphopeptides could be specifically retained on the SAX column at high pH around 8 and could be eluted by 5% formic acid. Thus, the protein digests without any pretreatment could be loaded onto the SAX column under basic pH condition; after removing nonphosphopeptides by washing, the bound phosphopeptides could be eluted directly onto a MALDI target and analyzed by MALDI-TOF MS. This approach significantly simplified the analytical procedures and reduced the sample loss. Because of the excellent MALDI MS compatible procedure and the microscale SAX column, a detection limit as low as 50 amol for the analysis of phosphopeptides from β-casein digest was achieved. To circumvent the inconvenience of the sample loading, a new simple sample introducing method based on capillary action was proposed, which further reduced the detection limit to 10 amol.Keywords
This publication has 23 references indexed in Scilit:
- Reversed-Phase-Reversed-Phase Liquid Chromatography Approach with High Orthogonality for Multidimensional Separation of PhosphopeptidesAnalytical Chemistry, 2009
- A binary matrix for improved detection of phosphopeptides in matrix‐assisted laser desorption/ionization mass spectrometryRapid Communications in Mass Spectrometry, 2009
- Comprehensive and Reliable Phosphorylation Site Mapping of Individual Phosphoproteins by Combination of Multiple Stage Mass Spectrometric Analysis with a Target-Decoy Database SearchAnalytical Chemistry, 2009
- Mass Spectrometry Analysis of Phosphopeptides after Peptide Carboxy Group DerivatizationAnalytical Chemistry, 2008
- Development of phosphopeptide enrichment techniques for phosphoproteome analysisThe Analyst, 2008
- Sensitive detection of phosphopeptides by matrix‐assisted laser desorption/ionization mass spectrometry: use of alkylphosphonic acids as matrix additivesRapid Communications in Mass Spectrometry, 2008
- Comprehensive Phosphorylation Site Analysis of Individual Phosphoproteins Applying Scoring Schemes for MS/MS DataAnalytical Chemistry, 2007
- Chemical derivatization of phosphoserine and phosphothreonine containing peptides to increase sensitivity for MALDI‐based analysis and for selectivity of MS/MS analysisProteomics, 2006
- Large-scale characterization of HeLa cell nuclear phosphoproteinsProceedings of the National Academy of Sciences, 2004
- Phosphoric Acid as a Matrix Additive for MALDI MS Analysis of Phosphopeptides and PhosphoproteinsAnalytical Chemistry, 2004