Ion Implants as Matrix‐Appropriate Calibrators for Geochemical Ion Probe Analyses
- 12 October 2014
- journal article
- research article
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 39 (3) , 265-276
Abstract
Ion microprobe elemental and isotopic determinations can be precise but difficult to quantify. Error is introduced when the reference material and the sample to be analysed have different compositions. Mitigation of such ‘matrix effects’ is possible using ion implants. If a compositionally homogeneous reference material is available which is ‘matrix‐appropriate’ (i.e., close in major element composition to the sample to be analysed, but having an unknown concentration of the element, E, to be determined) then ion implantation can be used to introduce a known amount of an E isotope, calibrating the E concentration and producing a matrix‐appropriate calibrator. Nominal implant fluences (ions cm−2) are inaccurate by amounts up to approximately 30%. However, ion implantation gives uniform fluences over large areas; thus, it is possible to ‘co‐implant’ an additional reference material of any bulk composition having known amounts of E, independently calibrating the implant fluence. Isotope ratio measurement standards can be produced by implanting two different isotopes, but permil level precision requires postimplant calibration of the implant isotopic ratio. Examples discussed include (a) standardising Li in melilite; (b) calibrating a 25Mg implant fluence using NIST SRM 617 glass and (c) using Si co‐implanted with 25Mg alongside NIST SRM 617 to produce a calibrated measurement of Mg in Si.Keywords
This publication has 15 references indexed in Scilit:
- Accurate analysis of shallowly implanted solar wind ions by SIMS backside depth profilingChemical Geology, 2014
- The Genesis solar wind sample return mission: Past, present, and futureMeteoritics & Planetary Science, 2013
- Isotopic and elemental fractionation of solar wind implanted in the Genesis concentrator target characterized and quantified by noble gasesMeteoritics & Planetary Science, 2011
- Noble gas composition of the solar wind as collected by the Genesis missionGeochimica et Cosmochimica Acta, 2009
- Lithium isotope analysis of olivine by SIMS: Calibration of a matrix effect and application to magmatic phenocrystsChemical Geology, 2009
- Quantitative study of oxygen enhancement of sputtered ion yields. I. Argon ion bombardment of a silicon surface with O2 floodSurface Science, 2004
- Beryllium Analyses by Secondary Ion Mass SpectrometryReviews in Mineralogy and Geochemistry, 2002
- Analytical Procedures for the Measurement of Boron Isotope Compositions by Ion Microprobe in Meteorites and Mantle RocksGeostandards Newsletter, 1997
- Calibration of the ion microprobe for quantitative trace precious metal analyses of ore mineralsEconomic Geology, 1989
- Factors affecting precision and accuracy in quantitative analysis by secondary ion mass spectrometryAnalytical Chemistry, 1989