Abstract
Background electrolytes (BGEs) prepared in pure organic solvents are common alternatives to aqueous BGEs in capillary electrophoresis. Several general advantages of organic solvents over water have been asserted in the literature, namely (i) organic solvents increase the separation selectivity; (ii) organic solvents increase the separation efficiency; (iii) high separation voltages and/or high BGE ionic strengths can be used in organic solvents due to lower electric current compared to water. Related assumptions are that (iv) due to higher field strengths applicable in organic solvents the analysis time is shorter than in aqueous BGEs, and (v) the solubility and/or stability of components (either analytes or BGE chemicals) is higher/better in organic solvents. In the present work, these asserted advantages were critically evaluated based on the physical principles of ion transport and zone dispersion in solution. The result was that many of the above‐mentioned general advantages are overestimated or even inexistent; often they have no fundamental basis.Keywords
This publication has 46 references indexed in Scilit:
- Effects of the limited analyte solubility on its mobility and zone shape: Electrophoretic behavior of sanguinarine and chelerythrine around pH 7Electrophoresis, 2005
- Comparison of methanol and acetonitrile as solvents for the separation of sertindole and its major metabolites by capillary zone electrophoresisElectrophoresis, 2005
- Band‐broadening in capillary zone electrophoresis with axial temperature gradientsElectrophoresis, 2004
- Peak dispersion and contributions to plate height in nonaqueous capillary electrophoresis at high electric field strengths: Ethanol as background electrolyte solventElectrophoresis, 2004
- A potentiometric study of acid–base properties of the (phenol+phenolate) systems in acetonitrile and, (acetonitrile+cyclohexane) solvent systemThe Journal of Chemical Thermodynamics, 2003
- Dependence of analyte separation on electroosmotic flow in capillary zone electrophoresis: Quantitative description by the reduced mobilityJournal of Microcolumn Separations, 1998
- Dissociation constants of neutral and charged acids in methyl alcohol. The acid strength resolutionAnalytica Chimica Acta, 1998
- Electrophoretic detection and evaluation of heteroconjugate anion formation between Brønsted acids and the perchlorate ion in acetonitrileChemical Communications, 1996
- Resolution as a function of the pH of the buffer based on the analyte charge number for multivalent ions in capillary zone electrophoresis without electroosmotic flow: Theoretical prediction and experimental evaluationAnalytical Chemistry, 1993
- The Variation of Equivalent Conductance with Concentration and TemperatureJournal of the American Chemical Society, 1954