3D Impedimetric Biosensor for Cyanobacteria Detection in Natural Water Sources
Open Access
- 25 December 2021
- journal article
- research article
- Published by MDPI AG in Chemosensors
- Vol. 10 (1) , 7
Abstract
The excessive growth of cyanobacteria in freshwater sources produces the development of toxic blooms mainly due to the production of cyanotoxins. Here, a novel impedimetric biosensor based on a three-dimensional interdigitated electrode array (3D-IDEA) for detection of cyanobacteria cells is reported. The 3D-IDEA sensor surface biofunctionalization was performed by means of the layer-by-layer method using polyethyleneimine (PEI) as the anchoring layer and concanavalin A (Con A) as the bioreceptor to lipopolysaccharides of cyanobacteria cells. The developed PEI-Con A 3D-IDEA sensors show a linear response (R2 = 0.992) of the impedance changes (RS) versus the logarithm of cyanobacteria concentrations in the range of 102–105 cells·mL−1 with the detection limit of 100 cells·mL−1. Moreover, to prevent the interference from components that may be present in real water samples and minimize a possible sample matrix effect, a filtration methodology to recover cyanobacterial cells was developed. The proposed methodology allows 91.2% bacteria recovery, permitting to obtain results similar to controlled assays. The developed system can be used in aquatic environments to detect cyanobacteria and consequently to prevent the formation of blooms and the production of cyanotoxins. Con A can bind to most polysaccharides and so react with other types of bacteria. However, currently, on the market, it is not possible to find specific biorecognition elements for cyanobacteria. Taking into consideration the specificity of samples to be analyzed (natural water resources), it is difficult to expect high concentration of other bacteria. In this sense, the developed methodology may be used as an alarm system to select samples for more thorough and precise laboratory analysis.Keywords
Funding Information
- Consejo Superior de Investigaciones Científicas (201850E071)
- WATERWORKS15 ERA-NET (PCIN-2017-031)
This publication has 42 references indexed in Scilit:
- Response of a microcapillary impedimetric transducer to changes in surface conductance at liquid/solid interfaceJournal of Colloid and Interface Science, 2013
- Methods for the determination of limit of detection and limit of quantitation of the analytical methodsChronicles of Young Scientists, 2011
- Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cellsBiosensors and Bioelectronics, 2009
- Three-dimensional interdigitated electrode array as a transducer for label-free biosensorsBiosensors and Bioelectronics, 2008
- Label‐Free Impedance Biosensors: Opportunities and ChallengesElectroanalysis, 2007
- Characteristics of polyelectrolyte multilayers: Effect of PEI anchoring layer and posttreatment after depositionJournal of Colloid and Interface Science, 2007
- Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA‐Sensors, and Enzyme BiosensorsElectroanalysis, 2003
- Biomedical Applications of Electrostatic Layer-by-Layer Nano-Assembly of Polymers, Enzymes, and NanoparticlesCell Biochemistry and Biophysics, 2003
- Adsorption and Electrokinetic Properties of Polyethylenimine on Silica SurfacesLangmuir, 2002
- Molecular film assembly via layer-by-layer adsorption of oppositely charged macromolecules (linear polymer, protein and clay) and concanavalin A and glycogenThin Solid Films, 1996