Modular versus monobloc dual mobility components for primary cementless total hip arthroplasty: a systematic review and meta-analysis of implants' survival, complication rates, clinical and radiographic outcomes
- 16 November 2024
- journal article
- review article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-11
Abstract
Purpose The dual mobility cup (DMC) reduces the dislocation rates in total hip arthroplasty (THA). DMC systems include anatomical (non-modular or monoblock) (ADM) and modular dual mobility (MDM) components (Stryker Orthopaedics, Mahwah, NJ, USA). This review aims to assess differences between these two types of DMC implants concerning dislocation and revision rates, as well as patient-reported outcomes. Methods This systematic review and meta-analysis of studies reports data from patients undergoing primary THA using MDM and/or ADM implants. Following the PRISMA guidelines, we analyzed articles from Science Direct/Scopus, PubMed, and the Cochrane Database of Systematic Reviews. We compared dislocation rates, revisions for any reason, aseptic loosening, infections, fractures, and functional outcomes between ADM and MDM components. Results Eleven studies were considered eligible for further analysis. A total of 3369 patients (mean age = 65.4 years) underwent primary THA, including 3386 DMC implants. The mean follow-up for the MDM and ADM groups was 2.9 years and 3.9 years, respectively. The study revealed one dislocation in the MDM and none in the ADM. By proportion metanalysis, the review did not show statistical differences in all-cause revisions (p = 0.93, [CI [0.01;0.02]) or periprosthetic fractures (p = 0.18, CI [0.01;0.02]). Conclusions MDM and ADM systems, both, represent safe DM options regarding dislocation, all-causes revisions and functional outcomes.Keywords
This publication has 49 references indexed in Scilit:
- Metal Ion Concentrations in Young, Active Patients Following Total Hip Arthroplasty with the Use of Modern Bearing CouplesThe Journal of Arthroplasty, 2015
- Clinical Outcomes, Survivorship and Adverse Events With Mobile-Bearings Versus Fixed-Bearings in Hip Arthroplasty—A Prospective Comparative Cohort Study of 143 ADM Versus 130 Trident Cups at 2 to 6-Year Follow-UpThe Journal of Arthroplasty, 2015
- Are Modern Dual Mobility Cups a Valuable Option in Reducing Instability After Primary Hip Arthroplasty, Even in Younger Patients?The Journal of Arthroplasty, 2014
- A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess wether a dual mobility cup has a decreased dislocation riskInternational Orthopaedics, 2014
- Dual-mobility bearings: a review of the literatureExpert Review of Medical Devices, 2012
- Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hipsInternational Orthopaedics, 2011
- Health-Related Quality of Life in Total Hip and Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2004
- Anterior iliopsoas impingement after total hip arthroplastyThe Journal of Arthroplasty, 1995
- Total hip replacement in congenital dislocation and dysplasia of the hip.Journal of Bone and Joint Surgery, 1979
- The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hipMedical & Biological Engineering & Computing, 1969