Right ventricular apical pacing: a necessary evil?
Authors:
- Jeff S HealeyJHJeff S Healey
- Raymond YeeRYRaymond Yee
- Anthony TangATAnthony Tang
- 1 January 2007
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Cardiology
- Vol. 22 (1) , 33-38
Abstract
Clinical trial evidence suggests that traditional right ventricular apical pacing may be harmful. This review summarizes the existing evidence and outlines the major avenues of ongoing research in this field. Despite theoretical advantages of dual-chamber pacing, large randomized trials found only a small advantage over single-chamber ventricular pacing. Subsequent analysis of one of these trials suggested that this was due to the tendency for dual-chamber pacemakers to produce frequent, unnecessary right ventricular pacing. This hypothesis is supported by a prospective study among defibrillator recipients, showing that dual-chamber pacing results in a very high frequency of ventricular pacing and worse clinical outcomes, compared with backup ventricular pacing. These observations have led to a renewed interest in single-chamber atrial pacing for sinus node dysfunction, the development of new dual-chamber pacemaker algorithms designed to minimize right ventricular pacing, and the search for better ways to pace the ventricles in patients who require ventricular pacing. Conventional right ventricular apical pacing should be avoided whenever possible. In patients who require ventricular pacing, ongoing research will determine if selected-site pacing or multisite pacing improves clinical outcomes compared with traditional right ventricular apical pacing.Keywords
This publication has 26 references indexed in Scilit:
- Single-Chamber versus Dual-Chamber Pacing for High-Grade Atrioventricular BlockNew England Journal of Medicine, 2005
- Incidence of atrial fibrillation and thromboembolism in a randomised trial of atrial versus dual chamber pacing in 177 patients with sick sinus syndromeHeart, 2004
- The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: Rationale, Design, Results, Clinical Implications and Lessons for Future TrialsCardiac Electrophysiology Review, 2003
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003
- Dual-Chamber Pacing or Ventricular Backup Pacing in Patients With an Implantable DefibrillatorJAMA, 2002
- Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node DysfunctionNew England Journal of Medicine, 2002
- Effects of Physiologic Pacing versus Ventricular Pacing on the Risk of Stroke and Death Due to Cardiovascular CausesNew England Journal of Medicine, 2000
- Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndromeThe Lancet, 1997
- Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndromeThe Lancet, 1994
- USE OF EXTERNAL ELECTRIC PACEMAKER IN CARDIAC ARRESTJAMA, 1955