A test method to monitor in vitro storage and degradation effects on a skin substitute
- 4 September 2007
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 30 (5) , 640-646
Abstract
We have investigated a potential test method to monitor changes through possible degradation of a collagen/glycosaminoglycan tissue engineering scaffold in vitro. The method used cyclic voltammetry where the degradation process was measured by determining changes in the apparent diffusion coefficients of thermodynamically reversible couples, ferrocyanide and 1,4-benzoquinone, through the scaffold before and after degradation at low pH and at different temperatures. Scaffold samples were degraded in vitro by exposure to pH 3 for 44 days and also stored in pH 7.4 phosphate saline buffer for one week. Sample temperatures used were 21 degrees C, 37 degrees C and 40 degrees C. The greatest apparent degradation was observed for scaffolds stored at 40 degrees C. Prior to storage, effective diffusion coefficients were 4.4x10(-6) cm2 s(-1) and 2.6x10(-10) cm2 s(-1) for ferrocyanide and 1,4-benzoquinone, respectively. For these respective compounds values changed to 1.2x10(-6) cm2 s(-1) and 1.0x10(-6) cm2 s(-1) after 37 degrees C degradation and 2.6x10(-6) cm2 s(-1) and 5.5x10(-8) cm2 s(-1) after pH 3 degradation.Keywords
This publication has 18 references indexed in Scilit:
- On-line fluorescent monitoring of the degradation of polymeric scaffolds for tissue engineeringThe Analyst, 2005
- Update on the use of collagen/glycosaminoglycate skin substitute—six years of experiences with artificial skin in 15 German burn centersBurns, 2004
- Molecular diffusion in tissue‐engineered cartilage constructs: Effects of scaffold material, time, and culture conditionsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- The determination of diffusion coefficients of counter ion in an ion exchange membrane using electrical conductivity measurementElectrochimica Acta, 2003
- Electrochemical characterisation of the diffusion of a biomolecule through a hydrogelJournal of Electroanalytical Chemistry, 2003
- Diffusion characteristics of nitrate and glycerol in alginateColloids and Surfaces B: Biointerfaces, 2002
- Noninvasive measurement of effective diffusivities in cell immobilization gels through use of near-infrared spectroscopyBiotechnology and Bioengineering, 2000
- Diffusion of solutes in agarose and alginate gels: 1H and 23Na PFGSE and 23Na TQF NMR studiesMagnetic Resonance in Medicine, 1997
- THE USE OF "ARTIFICIAL SKIN" FOR BURNSAnnual Review of Medicine, 1987
- Successful Use of a Physiologically Acceptable Artificial Skin in the Treatment of Extensive Burn InjuryAnnals of Surgery, 1981