Combination of 2D sensitivity encoding and 2D partial fourier techniques for improved acceleration in 3D contrast‐enhanced MR angiography
Open Access
- 8 December 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (1) , 16-22
Abstract
Sensitivity encoding (SENSE) and partial Fourier (PF) techniques both reduce MRI acquisition time. Two‐dimensional SENSE uses coil sensitivities to unfold aliasing in the phase/slice‐encoding plane. One‐dimensional PF and homodyne reconstruction are routinely applied in the frequency/phase‐encoding plane to compensate for nonsampled k‐space of the presumed real magnetization. Recently, a modified 3D elliptical centric acquisition was proposed to facilitate 2D‐PF and homodyne reconstruction on an undersampled phase/slice‐encoding plane. In this work we hypothesized that this 2D‐PF technique can be combined with 2D‐SENSE to achieve a greater acceleration factor than what each method can provide separately. Reconstruction of data whereby SENSE and PF are applied along the same axes is described. Contrast‐enhanced MR angiography (CE‐MRA) results from experiments using four receiver coils in phantom and volunteer studies are shown. In 11 volunteer studies, the SENSE‐PF‐homodyne technique using sevenfold acceleration (4× SENSE, 1.7× PF) consistently provided high‐diagnostic‐quality images with near 1‐mm isotropic resolution in acquisition times of <20 s. Magn Reson Med, 2006.Keywords
This publication has 26 references indexed in Scilit:
- Undersampled elliptical centric view‐order for improved spatial resolution in contrast‐enhanced MR angiographyMagnetic Resonance in Medicine, 2005
- Improved venous suppression and spatial resolution with SENSE in elliptical centric 3D contrast-enhanced MR angiographyMagnetic Resonance in Medicine, 2004
- Time-resolved 3D contrast-enhanced MRA of an extended FOV using continuous table motionMagnetic Resonance in Medicine, 2004
- Time‐resolved contrast‐enhanced magnetic resonance angiography in pediatric patients using sensitivity encodingJournal of Magnetic Resonance Imaging, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Improved centric phase encoding orders for three‐dimensional magnetization‐prepared mr angiographyMagnetic Resonance in Medicine, 1996
- Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriographyJournal of Magnetic Resonance Imaging, 1993
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- MR fluoroscopy: Technical feasibilityMagnetic Resonance in Medicine, 1988