A fractal contact theory based model for bolted connection looseness monitoring using piezoceramic transducers
- 30 August 2017
- journal article
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 26 (10) , 104010
Abstract
In this paper, based on the fractal contact theory, a new analytical model for bolted joints is proposed to monitor bolt looseness by using a pair of piezoceramic transducers for ultrasonic wave generation and detection. The time reversal method is used to obtain the focused signal peak amplitude during ultrasonic wave propagation through bolt connection surface. The influence of bolt load on the actual contact area of the bolted joint surface is determined by the fractal contact theory, and the finite element method is applied to obtain the relationship between the actual contact area and the focused signal peak amplitude. The focused signal peak obtained through the time reversal method increases with the increase of applied axial load before saturation. The investigation proposed in this paper is based on the inherent contact mechanism between the two contact surfaces, and achieves more accurate quantitative monitoring of bolt looseness. Finally, a comparison of the predicted and experimental results shown validates the proposed model in this paper.Keywords
This publication has 31 references indexed in Scilit:
- Wind turbine blade health monitoring with piezoceramic-based wireless sensor networkInternational Journal of Smart and Nano Materials, 2013
- Improvement of a vibration-based damage detection approach for health monitoring of bolted flange joints in pipelinesStructural Health Monitoring, 2013
- Integrated impedance and guided wave based damage detectionMechanical Systems and Signal Processing, 2012
- Concrete structural health monitoring using embedded piezoceramic transducersSmart Materials and Structures, 2007
- Estimation of clamping force in high-tension bolts through ultrasonic velocity measurementUltrasonics, 2006
- Detection of bolt loosening in C–C composite thermal protection panels: I. Diagnostic principleSmart Materials and Structures, 2006
- Integrated Structural Health Assessment Using Piezoelectric Active SensorsShock and Vibration, 2005
- Detection of bolt load loss in hybrid composite/metal bolted connectionsEngineering Structures, 2004
- Contactless measurement of bolt axial stress using a shear-wave electromagnetic acoustic transducerNDT & E International, 2001
- Coupled Electro-Mechanical Analysis of Adaptive Material Systems — Determination of the Actuator Power Consumption and System Energy TransferJournal of Intelligent Material Systems and Structures, 1994