Comparison of Femoral Head Penetration Using RSA and the Martell Method
Authors:
- Charles R BragdonCBCharles R Bragdon
- John M MartellJMJohn M Martell
- Meridith E GreeneMGMeridith E Greene
- Daniel M EstokDEDaniel M Estok
- Jonas ThannerJTJonas Thanner
- Johan KärrholmJKJohan Kärrholm
- William H HarrisWHWilliam H Harris
- Henrik MalchauHMHenrik Malchau
- 1 July 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 448, 52-57
Abstract
Radiostereometry has high precision and accuracy measuring polyethylene wear in total hip arthroplasty but requires a specialized setup. The Martell method is simpler and can be used on larger populations. The hypothesis that the radiostereometry analysis and the Martell analysis would yield comparable wear data from the same group of patients having total hip arthroplasty was tested. A group of twenty-five total hip arthroplasty patients who had both radiostereometry and standard anterior-posterior pelvic and cross-table lateral radiographs of sufficient quality for analysis were identified. The films were taken at postoperative periods of 6 weeks, 1 year, 2 years, and 5 years. Femoral head penetration was measured by both methods at each time point. The median penetration rates measured by each method decreased over time. Penetration results were affected by method of analysis, time, and dimension, with greater penetration for Martell compared with radiostereometry at each time point, greater penetration with increasing time for each method, and larger three-dimensional magnitude compared with two-dimensional analysis. Case series Level IV. See Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 20 references indexed in Scilit:
- Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantomJournal of Orthopaedic Research, 2004
- Measurement of Polyethylene Wear in Total Hip Arthroplasty: Accuracy Versus Ease of UseYonsei Medical Journal, 2003
- In vivo kinematics of total knee arthroplasty: Flat compared with concave tibial joint surfaceJournal of Orthopaedic Research, 2000
- Prediction of long‐term polyethylene wear in total hip arthroplasty, based on early wear measurements made using digital image analysisJournal of Orthopaedic Research, 1998
- Three-dimensional polyethylene wear of a press-fit titanium prosthesisThe Journal of Arthroplasty, 1997
- Accuracy of migration analysis in hip arthroplasty Digitized and conventional radiography, compared to radiostereometry in 51 patientsActa Orthopaedica, 1995
- Determining the movements of the skeleton using well-configured markersJournal of Biomechanics, 1993
- Roentgen Stereophotogrammetric Short‐Term Analysis of Growth Rate in Children Operated for Crohn's DiseaseActa Paediatrica, 1991
- Kinematics of the ankle and foot: In vivo roentgen stereophotogrammetryActa Orthopaedica, 1989
- Rate of Wear in Total Hip ReplacementClinical Orthopaedics and Related Research, 1975