Validation of a CFD model of an orbiting culture dish with PIV and analytical solutions
Authors:
- 3 May 2017
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 63 (9) , 4233-4242
Abstract
Particle image velocimetry (PIV) and an extended solution of Stokes’ second problem were used to validate a computational fluid dynamics (CFD) model of flow in an orbiting dish. Velocity vector components throughout one complete orbit differed between CFD and PIV by less than 5%. Computational velocity magnitudes averaged over the interior 20% radius, the region where the analytical solution is most applicable, were 0.3% higher than the analytical values, while the experimental values in the same region were 2.4% higher. Velocity profiles in the center of the dish across normalized heights that most influence wall shear stress varied on average by ∼–0.00046 for the normalized radial component and by ∼0.0038 for the normalized tangential component compared to the analytical solution. These results represent the most comprehensive validation to date for computational models of the orbiting dish system. © 2017 American Institute of Chemical Engineers AIChE J, 63: 4233–4242, 2017Keywords
This publication has 36 references indexed in Scilit:
- Fluid flow regulates e-selectin protein levels in human endothelial cells by inhibiting translationJournal of Vascular Surgery, 2003
- The Role of Fluid Mechanics in the Localization and Detection of AtherosclerosisJournal of Biomechanical Engineering, 1993
- Vascular endothelium responds to fluid shear stress gradients.Arteriosclerosis and Thrombosis: A Journal of Vascular Biology, 1992
- The Distribution of Fluid Forces on Model Arterial Endothelium Using Computational Fluid DynamicsJournal of Biomechanical Engineering, 1992
- Turbulent fluid shear stress induces vascular endothelial cell turnover in vitro.Proceedings of the National Academy of Sciences, 1986
- The Elongation and Orientation of Cultured Endothelial Cells in Response to Shear StressJournal of Biomechanical Engineering, 1985
- Heterogeneity of endothelium in human aorta A quantitative analysis by scanning electron microscopyAtherosclerosis, 1984
- FLUID DYNAMICS AS A FACTOR IN THE LOCALIZATION OF ATHEROGENESISaAnnals of the New York Academy of Sciences, 1983
- The Dynamic Response of Vascular Endothelial Cells to Fluid Shear StressJournal of Biomechanical Engineering, 1981
- Acute Vascular Endothelial Changes Associated with Increased Blood Velocity GradientsCirculation Research, 1968