Abstract
This brief presents a 16-electrode electrical impedance tomography (EIT) system for hand gesture recognition. The hardware of the system is based on integrated circuits including a 12-bit high spectral purity current-steering DAC implemented in 0.18 μm CMOS technology, a current driver and an instrumentation amplifier in 0.35 μm CMOS technology. Both 2D and 3D EIT electrode arrangements were tested for hand gesture recognition. It is shown that using machine learning algorithms, eight hand gestures can be distinguished from the measured bio-impedance data with an accuracy of 97.9% when the electrodes are placed on a single wristband, and an accuracy of 99.5% with the same number of electrodes distributed on two wristbands for 3D EIT measurement. In particular 3D EIT demonstrated significant superiority in its ability to discriminate between gestures with similar muscle contractions.Keywords
Funding Information
- Medical Research Council (MR/R011648/1)
This publication has 16 references indexed in Scilit:
- A 1.4-m $\Omega$ -Sensitivity 94-dB Dynamic-Range Electrical Impedance Tomography SoC and 48-Channel Hub-SoC for 3-D Lung Ventilation Monitoring SystemIEEE Journal of Solid-State Circuits, 2017
- A Quantitative Evaluation of Drive Pattern Selection for Optimizing EIT-Based Stretchable SensorsSensors, 2017
- Gesture recognition by instantaneous surface EMG imagesScientific Reports, 2016
- Advancing Hand Gesture Recognition with High Resolution Electrical Impedance Tomography2016
- Tomo2015
- The Extraction of Neural Information from the Surface EMG for the Control of Upper-Limb Prostheses: Emerging Avenues and ChallengesIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014
- Fully Implantable Multi-Channel Measurement System for Acquisition of Muscle ActivityIEEE Transactions on Instrumentation and Measurement, 2013
- A Compact Dynamic-Performance-Improved Current-Steering DAC With Random Rotation-Based Binary-Weighted SelectionIEEE Journal of Solid-State Circuits, 2011
- A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerveBiosensors and Bioelectronics, 2010
- Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram RecordingIEEE Transactions on Biomedical Engineering, 2008