Is Endovascular Arteriovenous Fistula a Feasible Alternative for Hemodialysis Patients?
Authors:
- Hugo Vergara-PérezHVHugo Vergara-Pérez
- Raúl Diaitz-Usetxi LaplazaRLRaúl Diaitz-Usetxi Laplaza
- Alejandro Pérez AlbaAAAlejandro Pérez Alba
- Pablo Baliño RemiroPRPablo Baliño Remiro
- Asunción Rius PerisAPAsunción Rius Peris
- M. Ángeles Fenollosa SegarraMSM. Ángeles Fenollosa Segarra
- Alejandro Tamayo VasquezAVAlejandro Tamayo Vasquez
- Javier RequeJRJavier Reque
- 12 September 2024
- journal article
- research article
- Published by S. Karger AG in Blood Purification
- Vol. 54 (1) , 1-7
Abstract
Introduction: For hemodialysis (HD) patients, the selection of vascular access is a crucial factor that significantly affects morbidity and mortality. Historically, native arteriovenous fistulas (AVFs) have been established using surgical techniques. However, devices facilitating percutaneous endovascular arteriovenous fistula (endoAVF) formation have recently been introduced in clinical practice, showing promising initial evidence. The primary objectives were technical success, efficacy, and cannulation rates. The secondary objectives included primary and cumulative patency, safety, and the number of procedures required to maintain fistula patency. Methods: A prospective, single-center, single-arm study included all patients who underwent endoAVF creation using the WavelinQ™ EndoAVF System at a University Hospital between December 2021 and August 2023. Results: A total of 20 patients who underwent an endoAVF were included. Technical success was 100%. In total, 75% (15) of the endoAVFs met the criteria for physiological suitability. The cannulation rate was 66% (10/15) for endoAVFs that reached physiological suitability. At 6 months of follow-up, the primary and cumulative patency rates were 65% and 75%, respectively; at 12 months, these were 50% and 70%, respectively. Serious adverse events were not observed. The reintervention rate was 0.33 procedures/patient-year. Conclusion: Based on our experience, creating AVFs using the WavelinQ 4-F EndoAVF System is safe and effective, with high technical success rates and acceptable patency and reintervention rates.Keywords
This publication has 26 references indexed in Scilit:
- Percutaneous arteriovenous fistula creation with the 4F WavelinQ EndoAVF SystemJournal of Vascular Surgery, 2022
- Percutaneous Arteriovenous Fistula Creation with the WavelinQ 4-French EndoAVF System: A Single-Center Retrospective Analysis of 30 PatientsJournal of Vascular and Interventional Radiology, 2022
- Real-World Usage of the WavelinQ EndoAVF SystemAnnals of Vascular Surgery, 2021
- Comparison of Outcomes of Percutaneous Arteriovenous Fistulae Creation by Ellipsys and WavelinQ DevicesJournal of Vascular and Interventional Radiology, 2020
- Endovascular Creation of Arteriovenous Fistulae for Hemodialysis Access with a 4 Fr Device: Clinical Experience from the EASE StudyAnnals of Vascular Surgery, 2019
- The Pivotal Multicenter Trial of Ultrasound-Guided Percutaneous Arteriovenous Fistula Creation for Hemodialysis AccessJournal of Vascular and Interventional Radiology, 2018
- Endovascular Creation of an Arteriovenous Fistula (endoAVF) for Hemodialysis Access: First ResultsCardioVascular and Interventional Radiology, 2017
- Percutaneous Creation of an Arteriovenous Fistula for Hemodialysis AccessJournal of Vascular and Interventional Radiology, 2015
- Characteristics and 3-year mortality and infection rates among incident hemodialysis patients with a permanent catheter undergoing a first vascular access conversionClinical and Experimental Nephrology, 2013
- Creating Arteriovenous Fistulas in 132 Consecutive PatientsArchives of Surgery, 2006