Influence of the Presence of Tissue Expanders on Energy Deposition for Post-Mastectomy Radiotherapy
Open Access
- 6 February 2013
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (2) , e55430
Abstract
An increasing number of studies have shown that post-mastectomy radiotherapy presents benefits associated with the patients survival and a significant fraction of the treated patients makes use of tissue expanders for breast reconstruction. Some models of tissue expanders have a magnetic disk on their surface that constitutes heterogeneity in the radiation field, which can affect the dose distribution during the radiotherapy treatment. In this study, the influence of a metallic heterogeneity positioned in a breast tissue expander was evaluated by means of Monte Carlo simulations using the MCNPX code and using Eclipse treatment planning system. Deposited energy values were calculated in structures which have clinical importance for the treatment. Additionally, the effect in the absorbed energy due to backscattering and attenuation of the incident beam caused by the heterogeneity, as well as due to the expansion of the prosthesis, was evaluated in target structures for a 6 MV photon beam by simulations. The dose distributions for a breast treatment were calculated using a convolution/superposition algorithm from the Eclipse treatment planning system. When compared with the smallest breast expander volume, underdosage of 7% was found for the largest volume of breast implant, in the case of frontal irradiation of the chest wall, by Monte Carlo simulations. No significant changes were found in dose distributions for the presence of the heterogeneity during the treatment planning of irradiation with an opposed pair of beams. Even considering the limitation of the treatment planning system, the results obtained with its use confirm those ones found by Monte Carlo simulations for a tangent beam irradiation. The presence of a heterogeneity didńt alters the dose distributions on treatment structures. The underdosage of 7% observed with Monte Carlo simulations were found for irradiation at 0°, not used frequently in a clinical routine.Keywords
This publication has 22 references indexed in Scilit:
- Does partial expander deflation exacerbate the adverse effects of radiotherapy in two-stage breast reconstruction?World Journal of Surgical Oncology, 2012
- Outcome of Different Timings of Radiotherapy in Implant-Based Breast ReconstructionsPlastic and Reconstructive Surgery, 2011
- Do metallic ports in tissue expanders affect postmastectomy radiation delivery?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Implication of planned radiotherapy on breast reconstruction: radiotherapy and plastic surgery with implantsBreast Cancer Online, 2005
- Locoregional Radiation Therapy in Patients With High-Risk Breast Cancer Receiving Adjuvant Chemotherapy: 20-Year Results of the British Columbia Randomized TrialJNCI: Journal of the National Cancer Institute, 2005
- Radiotherapy for breast cancer in patients undergoing breast reconstruction or augmentationCancer Treatment Reviews, 2004
- Dosimetry around metallic ports in tissue expanders in patients receiving postmastectomy radiation therapy: an ex vivo evaluationMedical Dosimetry, 2004
- Infectious Complications following Breast Reconstruction with Expanders and ImplantsPlastic and Reconstructive Surgery, 2003
- Microcalcifications in Breast Tissue Phantoms Visualized with Acoustic Resonance Coupled with Power Doppler US: Initial ObservationsRadiology, 2002
- Postoperative Radiotherapy in High-Risk Premenopausal Women with Breast Cancer Who Receive Adjuvant ChemotherapyNew England Journal of Medicine, 1997