A novel approach of centrifugal fluidized chamber to remove diesel engine particulate matter emission

Authors:

Abstract
Centrifugal fluidized bed with static geometry (CFB-SG) is a novel approach of fluidization which still remains unattended as an after treatment method to reduce diesel particulate matter. The centrifugal fluidized chambers are tested on a single cylinder diesel engine to reduce diesel particulate matter. The present investigation comprises a detailed examination on the impact of chamber geometry and mass of bed particles on smoke opacity, pressure drop, and fuel consumption. The numbers of the inlet are varied from 1 to 4, inlet slot width is fixed with two values of 3 mm and 5 mm. Mass of Silicon carbide used as bed particles is varied up to 0.5 kg. The results inferred that, with an increase in a number of inlets and inlet slot width, the pressure drop and smoke opacity decreases. The engine found out to be fuel efficient as a number of inlet and inlet slot width increases. Experimental investigations reveal that when 3 and 4 inlet chambers were used the centrifugal fluidized bed became more stable and uniform. Hence 3 and 4 inlet chambers show the maximum filtration efficiency i.e. chamber efficiency at medium engine load with 0.5 kg of bed particles. The maximum chamber efficiency of 62.09% was observed with 4 inlet chamber. As a consequence of Particulate matter deposition on bed particles and accumulation at an outlet, the chamber efficiency is reduced with time. These experimental results show the potential of centrifugal fluidized chambers to reduce PM diesel engines.