Most effective stimulation site for severe intention tremor

Authors:

Abstract
Objective: To evaluate the optimal target for intention tremor in thalamic deep brain stimulation Background: DBS of the thalamic ventral intermedius nucleus (Vim-DBS) is an established therapy for patients with severe, otherwise intractable intention tremor. However, the optimal stimulation site for severe intention tremor is still a matter of debate. Methods: We studied 7 patients with ET and 6 patients with MS following implantation of stimulation electrodes for Vim-DBS. We analyzed the localization of the contacts of the quadripolar electrode (Medtronic, model 3387) on stereotactic x-ray images. Based on intraoperative recordings we determined the position of the contacts relative to the ventral border of the Vim and the dorsal border of the subthalamic nucleus (STN). Three months after surgery, we evaluated the efficacy of each contact by assessment of a lateralized Fahn-score as well as analysis of accelerometry and grasping movements using a magnetic tracking system. Results: Most efficacious contacts were located below the ACPC-line. Mean coordinates (mm relative to the midACPC) for the efficacious contacts were on the right side (x, y, z): 12.9±1.6, -7.4±1.0; -1.6±1.3 and on the left side: -12.3±1.2, -7.3±1.7, -2.6±1.1. Correlation of the position of the efficacious contact with intraoperative microrecording revealed localization 1.2±1.0mm ventral to the Vim border and 1.2±1.6mm dorsal to the STN border. Stimulation of contacts below ACPC-line led to a mean reduction of the lateralized Fahn-score by 63.6±21.1% on the right side and 67.9±18.3% on the left side. Stimulation of contacts above ACPC-line had a less marked effect with a reduction of 20.5±16.4% and 17.6±16.2%, respectively. All patients had a high amplitude wing-beating tremor in the off stimulation condition with an accelerometer total power [log (mg2)/(µV2)] of 4.5e+2 for the right side and 5.9e+2 for the left side. Stimulation of contacts below ACPC-line led to a pronounced reduction of power to 2.5e+1 and 3.4e+0, respectively. Stimulation above ACPC-line had only little effect on accelerometer power. Tracking of grasping movements showed a marked reduction of intentional tremor by stimulation of contacts below but not above ACPC-line. Conclusion: Based on clinical and electrophysiological evaluation, this study demonstrates that the optimal target for alleviating severe intention tremor of ET and MS is located in the area below the thalamus and not within the Vim proper.