Quantitative contrast‐enhanced perfusion measurements of the human lung using the prebolus approach
Open Access
- 25 June 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (1) , 104-111
Abstract
Purpose To investigate dynamic contrast‐enhanced MRI (DCE‐MRI) for quantification of pulmonary blood flow (PBF) and blood volume (PBV) using the prebolus approach and to compare the results to the global lung perfusion (GLP). Materials and Methods Eleven volunteers were examined by applying different contrast agent doses (0.5, 1.0, 2.0, and 3.0 mL gadolinium diethylene triamine pentaacetic acid [Gd‐DTPA]), using a saturation‐recovery (SR) true fast imaging with steady precession (TrueFISP) sequence. PBF and PBV were determined for single bolus and prebolus. Region of interest (ROI) evaluation was performed and parameter maps were calculated. Additionally, cardiac output (CO) and lung volume were determined and GLP was calculated as a contrast agent–independent reference value. Results The prebolus results showed good agreement with low‐dose single‐bolus and GLP: PBF (mean ± SD in units of mL/minute/100 mL) = single bolus 190 ± 73 (0.5‐mL dose) and 193 ± 63 (1.0‐mL dose); prebolus 192 ± 70 (1.0–2.0‐mL dose) and 165 ± 52 (1.0–3.0‐mL dose); GLP (mL/minute/100 mL) = 187 ± 34. Higher single‐bolus resulted in overestimated values due to arterial input function (AIF) saturation. Conclusion The prebolus approach enables independent determination of appropriate doses for AIF and tissue signal. Using this technique, the signal‐to‐noise ratio (SNR) from lung parenchyma can be increased, resulting in improved PBF and PBV quantification, which is especially useful for the generation of parameter maps. J. Magn. Reson. Imaging 2009;30:104–111.Keywords
This publication has 23 references indexed in Scilit:
- Effect of Inspiratory and Expiratory Breathhold on Pulmonary PerfusionInvestigative Radiology, 2005
- Quantification of Pulmonary Blood Flow and Volume in Healthy Volunteers by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using a Parallel Imaging TechniqueInvestigative Radiology, 2004
- Quantitative assessment of regional pulmonary perfusion in the entire lung using three‐dimensional ultrafast dynamic contrast‐enhanced magnetic resonance imaging: Preliminary experience in 40 subjectsJournal of Magnetic Resonance Imaging, 2004
- Regional Lung Perfusion: Assessment with Partially Parallel Three-dimensional MR ImagingRadiology, 2004
- Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilation‐perfusion scintigraphy: An intra‐modality and inter‐modality agreement studyJournal of Magnetic Resonance Imaging, 2002
- Evaluation of regional pulmonary perfusion using ultrafast magnetic resonance imagingMagnetic Resonance in Medicine, 2001
- Quantitative assessment of pulmonary perfusion with dynamic contrast-enhanced MRIMagnetic Resonance in Medicine, 1999
- Prospective comparison of MR lung perfusion and lung scintigraphyJournal of Magnetic Resonance Imaging, 1999
- Pulmonary perfusion: Qualitative assessment with dynamic contrast‐enhanced MRI using ultra‐short TE and inversion recovery turbo FLASHMagnetic Resonance in Medicine, 1996
- On the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and VolumeJournal of Applied Physiology, 1954