Calcification at the Interface Between Titanium Implants and Bone: Observation With Confocal Laser Scanning Microscopy
Authors:
- Tetsunari NishikawaTNTetsunari Nishikawa
- Kazuya MasunoKMKazuya Masuno
- Masahiko MoriMMMasahiko Mori
- Yasuhiro TajimeYTYasuhiro Tajime
- Kenji KakudoKKKenji Kakudo
- Akio TanakaATAkio Tanaka
- 1 October 2006
- journal article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 32 (5) , 211-217
Abstract
It has not been previously possible to observe bone formation in undecalcified sections with titanium implants at high magnification because of the difficulty in sectioning bone together with implants. A method for examining the bone-implant interface in undecalcified sections is described in which implants are left in situ and confocal laser scanning microscopy (CLSM) is used to examine both the implant surface and adjacent bone. Pulsing of animals at different times with the fluorescent dyes calcein and alizarin red permitted assessment of temporal patterns of bone formation by CLSM. Reflectivity of the polished implant surface permitted accurate assessment of the position of the implant relative to labeled bone. The analysis showed that bone first formed as thin processes towards and across the implant surface, followed by further bone formation behind these processes. The interface between calcified bone tissue and the implant surface was characterized by a 10-μm space. The CLSM technique enabled detailed observations of new bone formation at the titanium implant interface.Keywords
This publication has 26 references indexed in Scilit:
- Bone Remodeling in Immediately Loaded and Unloaded Titanium Dental Implants: A Histologic and Histomorphometric Study in HumansJournal of Oral Implantology, 2005
- Histomorphometric, ultrastructural and microhardness evaluation of the osseointegration of a nanostructured titanium oxide coating by metal-organic chemical vapour deposition: an in vivo studyBiomaterials, 2004
- Histologic Evaluation of an Immediately Loaded Titanium Implant Retrieved from a Human After 6 Months in FunctionJournal of Oral Implantology, 2004
- The in vivo performance of a sol–gel glass and a glass-ceramic in the treatment of limited bone defectsBiomaterials, 2004
- Understanding and controlling the bone–implant interfaceBiomaterials, 1999
- A Study of the Regional Distribution of Bone Formed Around Hydroxyapatite Implants in the Tibiae of Streptozotocin‐Induced Diabetic Rats Using Multiple Fluorescent Labeling and Confocal Laser Scanning MicroscopyJournal of Periodontology, 1997
- Light and electron microscopic studies of bone-titanium interface in the tibiae of young and mature ratsJournal of Biomedical Materials Research, 1996
- Histochemical and confocal laser scanning microscopy study of the bone—titanium interface: an experimental study in rabbitsBiomaterials, 1994
- Biological aspects of implant dentistry: osseointegrationPeriodontology 2000, 1994
- Light and Transmission Electron Microscopy of the Intact Interfaces Between Non-submerged Titanium-coated Epoxy Resin Implants and Bone or GingivaJournal of Dental Research, 1992