The measurement of endogenous carbon monoxide production
- 1 June 2012
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 112 (11) , 1949-1955
Abstract
Recent findings that heme oxygenase-1 can be induced by oxidative stress and inflammation in many different cellular systems, and that carbon monoxide (CO) produced as a by-product of this enzyme is a signaling molecule, have generated a major research area with hundreds of studies published over the last few years. The measurement of expired CO concentration has been used in humans as a biomarker of induced heme oxygenase resulting from inflammation or oxidative stress, but a precise method of measuring endogenous CO production that can be easily used to study patients is needed. The present study describes such a method. The described method allows calculation of the rate of heme catabolism with a precision of ±2 μmol/h, ∼10% of the mean normal rate in subjects used in this investigation. This method, which is subject-patient friendly, precise, and inexpensive to perform, should be applicable to studies performed on humans with induced heme oxygenase and studies of effects of therapy for inflammatory and hemolytic diseases.Keywords
This publication has 26 references indexed in Scilit:
- Heme Oxygenase-1/Carbon MonoxideAmerican Journal of Respiratory Cell and Molecular Biology, 2009
- Increased heme catabolism in critically ill patients: correlation among exhaled carbon monoxide, arterial carboxyhemoglobin, and serum bilirubin IXα concentrationsAmerican Journal of Physiology-Lung Cellular and Molecular Physiology, 2006
- Exhaled carbon monoxide levels in children with sickle cell diseaseEuropean Journal of Pediatrics, 2004
- Increased Carbon Monoxide in Exhaled Air of Critically Ill PatientsBiochemical and Biophysical Research Communications, 2000
- Carbon Monoxide Production Associated with Ineffective Erythropoiesis*Journal of Clinical Investigation, 1967
- Endogenous carbon monoxide production in patients with hemolytic anemia.Journal of Clinical Investigation, 1966
- ENDOGENOUS CARBON MONOXIDE PRODUCTION IN MAN*Journal of Clinical Investigation, 1963
- Simplification of Haldane's Apparatus for Measuring CO2 Concentration in Respired Gases in Clinical PracticeBMJ, 1960
- Endogenous Formation of Carbon Monoxide in Man Under Normal and Pathological ConditionsScandinavian Journal of Clinical and Laboratory Investigation, 1949
- A Method for the Determination of the Total Haemoglobin Content of the BodyActa Physiologica Scandinavica, 1948