Background: Adjacent segment degeneration (ASD) following lumbar fusion has been well documented in recent years. However, the pathogenesis of ASD is not clear. To investigate this issue, we established a finite element model of segments L2–L5, simulated a single‐segment posterior fixation in L3–L4 and investigated the stress variation and the effects of the instrumented lumbar posterior fixation on adjacent levels.Methods: Models A, B and C of L2–L5 multisegment finite element intact models were established. In model A, segment L3–L4 was not fixed and was without disc degeneration in the adjacent segment (L2–L3, L4–L5); in model B there was posterior pedicle fixation in segment L3–L4 without disc degeneration in the adjacent segment (L2–L3, L4–L5); in model C there was posterior pedicle fixation in segment L3–L4 with a degenerated disc in the adjacent segment (L2–L3, L4–L5). Four levels of axial pressure, 0.3, 0.5, 1.0 and 2.0 MPa, were compared between each model of the stress variation on the discs of the adjacent segment (L2–L3, L4–L5).Results: The maximum principal stress mean value of disc L2–L3 under four pressures in model A was determined. The statistical results showed that stress was not significant difference in disc L2–L3 between models A and B, but there was a significant difference in disc L2–L3 between models A and C and a significant difference between each group in disc L4–L5 under four pressure conditions.Conclusions: The preoperative degeneration of the adjacent segment of the disc is a significant risk factor for ASD. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- The Clinical Characteristics and Risk Factors for the Adjacent Segment Degeneration in Instrumented Lumbar FusionJournal of Spinal Disorders & Techniques, 2008
- Adjacent segment hypermobility after lumbar spine fusion: No association with progressive degeneration of the segment 5 years after surgeryActa Orthopaedica, 2007
- Three-dimensional finite element analysis of the pediatric lumbar spine. Part I: pathomechanism of apophyseal bony ring fractureEuropean Spine Journal, 2006
- Adjacent Segment Disease after Lumbar or Lumbosacral Fusion: Review of the LiteratureSpine, 2004
- The Impact of Adjacent Level Disc Degeneration on Health Status Outcomes Following Lumbar FusionSpine, 2003
- Intervertebral disc degeneration adjacent to a lumbar fusion. An experimental rabbit model.The Journal of Bone and Joint Surgery. British volume, 2002
- Outcome of One-Level Posterior Lumbar Interbody Fusion for Spondylolisthesis and Postoperative Intervertebral Disc Degeneration Adjacent to the FusionSpine, 2000
- The Anisotropic Hydraulic Permeability of Human Lumbar Anulus FibrosusSpine, 1999
- Magnetic Resonance Imaging Assessment of Disc Degeneration 10 Years After Anterior Lumbar Interbody FusionSpine, 1995
- Lumbosacral Spinal Fusion A Biomechanical StudySpine, 1984