SAGITTAL PLANE KNEE LAXITY AFTER LIGAMENT RETAINING UNCONSTRAINED ARTHROPLASTY: A MATHEMATICAL ANALYSIS
Author:
- 1 April 2012
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 12 (02)
Abstract
Passive knee laxity is an important clinical measure to assess function after joint replacement. Clinical observations suggest that the use of minimally invasive surgical techniques in knee arthroplasty may affect the surgeon's ability to orient and position the prosthetic components accurately. Further, recent studies suggest that malplaced prosthetic components in ligament retaining unconstrained unicompartmental knee arthroplasty (UKA) can affect the ligament forces and, hence, the knee laxity. In the present study, a sagittal plane mathematical model of the knee with intact ligaments and unconstrained prosthetic components is used to analyze antero-posterior (A–P) knee laxity during passive flexion at different force levels. Also, the effects of errors in component placement are evaluated. The model calculations show a reasonable agreement with the experimental observations reported in literature. The results show that the A–P laxity during 0°–120° flexion first increases from 0° to about 30°, remains nearly constant for another 10° and then decreases somewhat linearly for higher flexion angles. Some errors in the placement of femoral component of the order of 1 mm can affect the knee laxity by nearly 3 mm in some flexion positions. The analysis has clinical relevance and suggests that the UKA requires close attention to component placement.Keywords
This publication has 18 references indexed in Scilit:
- Translational and rotational knee joint stability in anterior and posterior cruciate-retaining knee arthroplastyThe Knee, 2011
- Influence of component alignment on outcome for unicompartmental knee replacementThe Knee, 2009
- Changes in Knee Kinematics Reflect the Articular Geometry after ArthroplastyClinical Orthopaedics and Related Research, 2008
- Measurement of Knee Laxity and Pivot-Shift Kinematics With Magnetic SensorsOperative Techniques in Orthopaedics, 2008
- Effect of knee laxity on in vivo kinematics of meniscal-bearing knee prosthesesThe Knee, 2007
- Measuring knee joint laxity: A review of applicable models and the need for new approaches to minimize variabilityClinical Biomechanics, 2007
- The Effect of Sagittal Laxity on Function After Posterior Cruciate–Retaining Total Knee ReplacementThe Journal of Arthroplasty, 2006
- Comparing in vivo kinematics of anterior cruciate‐retaining and posterior cruciate‐retaining total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2006
- UKR—time for caution?The Knee, 2004
- Implant position in knee surgeryThe Journal of Arthroplasty, 2003