Fluctuation of Spuriously Elevated Troponin I: A Case Report
Open Access
- 7 June 2012
- journal article
- case report
- Published by Wiley in Case Reports in Critical Care
- Vol. 2012, 1-4
Abstract
Serum troponin is a useful laboratory study for the diagnosis of acute myocardial infarction. However, elevations can also be seen in a variety of other diseases processes. Falsely positive troponin values caused by interference with current troponin assays have been reported. We report a unique case that demonstrates the fluctuation of falsely elevated troponin correlating with hemoglobin, serving as a marker of heterophile antibody levels. A 74-year-old gentleman presented to our Emergency Department with a several-day history of increasing shortness of breath associated with a new-onset chest pain and a troponin I level of 77.28 ng/mL. Throughout his stay, fluctuations in measured troponin levels correlated strongly with fluctuations in hemoglobin levels. Several investigations confirmed false elevated troponin levels secondary to heterophile antibody interference. We conclude that hemoglobin trending in our patient represented a surrogate measure of his heterophile antibody titers with time and that fluctuations in these levels correlated with respective fluctuations in the falsely elevated troponin levels.Keywords
This publication has 21 references indexed in Scilit:
- Pathobiology of Troponin ElevationsJACC, 2011
- Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency departmentThe American Journal of Emergency Medicine, 2008
- Heterophilic antibody interference in an ultra-sensitive 3-site sandwich troponin I immunoassayClinica Chimica Acta, 2008
- Universal Definition of Myocardial InfarctionCirculation, 2007
- You Can Assay That Again!The American Journal of Medicine, 2007
- National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Clinical Characteristics and Utilization of Biochemical Markers in Acute Coronary SyndromesCirculation, 2007
- Unnecessary coronary angiography due to false positive troponin I results in a 51-year-old manClinica Chimica Acta, 2007
- Falsely Elevated Cardiac Troponin I LevelsClinical Cardiology, 2007
- Heterophile antibodies produce spuriously elevated concentrations of cardiac Troponin I in patients with Legionella pneumophilaClinical Biochemistry, 2005
- A comparison of the Monospot with the Paul-Bunnell test in infectious mononucleosis and other diseasesJournal of Clinical Pathology, 1969