Characterization and long-term performance of the Radon Trapping Facility operating at the Modane Underground Laboratory
Authors:
- R HodákRHR Hodák
- F PerrotFPF Perrot
- V BrudaninVBV Brudanin
- J BustoJBJ Busto
- M HavelcováMHM Havelcová
- J HůlkaJHJ Hůlka
- S JullianSJS Jullian
- O KochetovOKO Kochetov
- D LalanneDLD Lalanne
- P LoaizaPLP Loaiza
- J MaclJMJ Macl
- F MamedovFMF Mamedov
- 27 September 2019
- journal article
- research article
- Published by IOP Publishing in Journal of Physics G: Nuclear and Particle Physics
- Vol. 46 (11) , 115105
Abstract
Radon is one of the main potential sources of background radiation for any rare event experiments like neutrinoless double beta decay or dark matter experiments. The Radon Trapping Facility (RTF) installed in 2004 at the Modane Underground Laboratory (LSM) has been running for nine years providing radon-purified air at a level of 10 mBq m −3 for several experiments. The radon suppression principle is based on a radon physical adsorption using cooled compressed air at −55 °C pumped through a column filled with the K48 activated charcoal. After disassembling of the RTF, the 2.6 m high charcoal column has been divided into several layers in order to study with different techniques the dynamic adsorption coefficient (the K -factor) as a function of the depth and the radon spatial trapping profile by measuring the 210 Pb activity. It has been demonstrated that after almost a decade of running, the K -factor of the activated charcoal remains constant except for the first few cm of the column. Furthermore, it has been demonstrated that the mass activity of 210 Pb as a function of the depth of the charcoal column exhibits an exponential decay profile. The radon mean retention time τ R of (47.6 ± 1.2) days and the radon mean free path of (28.9 ± 0.4) cm have been derived and found to be consistent at 1 σ with the ones obtained from the K -factor study, i.e. from a total independent measurement. The radon suppression factor of the RTF of 6790 − 1720 + 2370 has been also estimated with a value consistent at 2 σ with the suppression factor measured during the RTF operation. Thus, this study has proven the capacity of the RTF to purify the LSM air from radon by more than three orders of magnitude during nine years of operation.Keywords
Funding Information
- Ministerstvo Školství, Mládeže a Tělovýchovy (LM2015072)
This publication has 18 references indexed in Scilit:
- Neutrinoless Double-Beta Decay: Status and ProspectsAnnual Review of Nuclear and Particle Science, 2019
- Current status of neutrinoless double-beta decay searchesReviews in Physics, 2016
- Dark matter direct-detection experimentsJournal of Physics G: Nuclear and Particle Physics, 2015
- Results of the search for neutrinoless double-decay inwith the NEMO-3 experimentPhysical Review D, 2015
- Theory of neutrinoless double-beta decayReports on Progress in Physics, 2012
- Measurement of the background in the NEMO 3 double beta decay experimentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Radon reduction and radon monitoring in the NEMO experimentAIP Conference Proceedings, 2007
- Technical design and performance of the NEMO 3 detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Development of super-high sensitivity radon detector for the Super-Kamiokande detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Measurement of radon concentrations at Super-KamiokandePhysics Letters B, 1999