Experimental investigation of thermal effects in HIFU-based external valvuloplasty with a non-spherical transducer, using high-resolution MR thermometry
- 6 August 2009
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (17) , 5123-5138
Abstract
Real-time image-guided extracorporeal high intensity focused ultrasound (HIFU) has been suggested for minimally invasive treatment of valvular dysfunction in the saphenous vein. Local application of heat on the perimeter of the valve zone was previously reported to induce a partial shrinkage of the collagen, which may correct valvular function. In our study, a novel MR compatible HIFU device has been investigated. This device is based on a non-spherical geometry, with two active elements that create a focusing line which is orthogonal to the beam main axis, aiming to cover the valve longitudinally. The prototype performance was characterized by electro-acoustical measurements of the pressure field and by high-resolution MR thermometry. Pressure and thermal fields were found in good agreement with the theoretical predictions. To investigate the therapeutic potential, fresh samples of excised human veins were filled with an agarose gel, embedded in porcine muscle and exposed to HIFU. The power level applied during a fixed duration of 30 s was varied such that the absolute temperature at focus ranged between 52 degrees C and 83 degrees C. Targeting was achieved under MR guidance using a MR compatible XZ positioning system. A dedicated waterproof miniature loop coil was specifically built to achieve high-resolution MRI image-based targeting (0.25 mm x 0.25 mm x 3 mm voxel) and thermometry (0.4 mm x 0.4 mm x 4 mm voxel). The vein wall was clearly identified on MR images before and after HIFU treatment. The thermal buildup created by the non-spherical transducer could be characterized from MR thermometry data. Shrinkage of the vein wall (above 65 degrees C) was determined by absolute temperature and was not a cumulative thermal dose effect.Keywords
This publication has 40 references indexed in Scilit:
- Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapyPhysics in Medicine & Biology, 2008
- Effect of variable heat transfer coefficient on tissue temperature next to a large vessel during radiofrequency tumor ablationBioMedical Engineering OnLine, 2008
- Pulsatile Flow Phantom for Ultrasound Image-Guided HIFU Treatment of Vascular InjuriesUltrasound in Medicine & Biology, 2007
- Architectonic Arrangement of the Vasa Vasorum of the Human Great Saphenous VeinJournal of Vascular Research, 2007
- Accessory and great saphenous veins as coronary artery bypass conduitsInteractive CardioVascular and Thoracic Surgery, 2006
- Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicatorsPhysics in Medicine & Biology, 2005
- The immediate effects of endovenous diode 808-nm laser in the greater saphenous vein: Morphologic study and clinical implicationsJournal of Vascular Surgery, 2005
- New Insights into Perforator Vein IncompetenceEuropean Journal of Vascular and Endovascular Surgery, 1999
- Noninvasive MRI thermometry with the proton resonance frequency method: Study of susceptibility effectsMagnetic Resonance in Medicine, 1995
- Epidemiology of varicose veinsBritish Journal of Surgery, 1994