Quantitative Analysis of Torsional Stiffness in Supplemental One-Third Tubular Plate Fixation in the Management of Isolated Syndesmosis Injuries
- 10 January 2013
- journal article
- research article
- Published by SAGE Publications in Foot & Ankle International
- Vol. 34 (2) , 267-272
Abstract
Background: Disruption of the distal tibia and fibula articulation or syndesmosis can occur without fracture, and isolated syndesmotic disruption is often treated operatively. Following syndesmotic screw removal, a period of protected weight-bearing usually follows to allow the screw holes to heal. Our hypothesis was that supplementing transsyndesmotic fixation with a one-third tubular plate would potentially increase the torsional stiffness about the ankle, thus reducing the risk of fracture after screw removal and potentially allowing a faster return to weight-bearing and sport. Methods: Ten pairs of fresh frozen cadaveric specimens were divided into 2 groups. In group 1 (7 pairs), each left extremity underwent the placement, and subsequent removal, of a 4.5-mm transsyndesmotic screw in a tricortical fashion. The matching right extremity underwent the same procedure but with the addition of a one-third tubular plate, which remained in situ after screw removal. In group 2 (3 pairs), the left specimens had a screw placed and removed while the right limbs remained intact. All specimens were tested under an axial preload and a torsional load until failure. Results: In group 1, the results demonstrated an increase in torsional stiffness in 5 of 7 specimens with supplemental fixation of a one-third tubular plate. In group 2, the presence of the screw hole alone reduced the torsional stiffness in all specimens tested when compared with intact specimens. However, neither of these differences were statistically significant. Conclusion: From this study, we can conclude that the use of supplementary one-third tubular plate fixation demonstrated a trend toward increasing the torsional stiffness following transsyndesmotic screw removal. Clinical Relevance: We believe the trend toward improved stiffness justifies the continued use of our technique, although further studies are necessary to confirm it.Keywords
This publication has 30 references indexed in Scilit:
- Distal tibial fracture post syndesmotic screw removal: an adverse complicationArchives of orthopaedic and trauma surgery, 2011
- Management of Common Sports-related Injuries About the Foot and AnkleJournal of the American Academy of Orthopaedic Surgeons, 2010
- The effect of 4 mm bicortical drill hole defect on bone strength in a pig femur modelArchives of orthopaedic and trauma surgery, 2010
- Stress fracture of the distal tibia following syndesmosis screw removalCurrent Orthopaedic Practice, 2010
- Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixationInjury, 2005
- Syndesmosis injuries in athletesFoot and Ankle Clinics, 2002
- Persistent Disability Associated with Ankle Sprains: A Prospective Examination of an Athletic PopulationFoot & Ankle International, 1998
- PRIMARY CARE OF FOOT AND ANKLE INJURIES IN THE ATHLETEClinics in Sports Medicine, 1997
- Bone StrengthJournal of Bone and Joint Surgery, 1972
- The Biomechanics of Torsional FracturesJournal of Bone and Joint Surgery, 1970